DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply with 24V DC / 5A output and universal 90–264 VAC input. Built-in active PFC, 88% typical efficiency, slim 40 mm metal housing, fanless natural convection cooling, complete protection functions, UL508 approved, TS35 DIN rail mounting, 3-year warranty — ideal for industrial control, factory automation and electrical panels.

24V / 5A
Output

120 W
Rated Power

90–264 VAC
Universal Input

88%
Efficiency

40 × 125 × 113 mm
Slim Housing

TS35
DIN Rail

atau

Share:

DAPPRA NDR-120-24 — 120W Slim DIN Rail Power Supply (24V / 5A) | SKU OF55
Overview

NDR-120-24 Overview

The DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 5A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.

The unit features a 40 mm wide metal housing, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-24 delivers reliable 24V power with 88% typical efficiency for demanding industrial loads.

Key Features

NDR-120-24 Key Features

Engineered for efficient, space-saving 24V industrial power supply applications.

  • 120W Output · 24V / 5ASingle output configuration providing 24V DC nominal output at 5A rated current (0~5A current range) with 120W rated output power.
  • Built-in Active PFCActive power factor correction with PF >0.93, reducing harmonic current and improving power quality.
  • Universal AC Input 90–264 VACFull-range single-phase AC input supports global mains voltages. Also supports 127–370 VDC input.
  • 24~28V Output AdjustmentFront-panel +V ADJ potentiometer allows the rated output voltage to be adjusted between 24V and 28V to suit the connected load.
  • 88% Typical EfficiencyThe NDR-120-24 achieves 88% typical efficiency, balancing performance with low power dissipation.
  • Slim 40 mm Metal HousingThe 40 × 125.2 × 113.5 mm metal housing enhances power dissipation and saves DIN rail space inside control cabinets.
  • Fanless Natural Convection CoolingNo fan means no dust intake, no acoustic noise and no moving parts — ideal for dusty industrial environments and silent operation.
  • Complete Protection FunctionsShort circuit, overload (105–160% rated output power, constant current limiting, auto-recovery), over voltage (29–33V) and over temperature protection are built in.
  • TS35 DIN Rail MountingDesigned for standard TS35/7.5 or TS35/15 DIN rail mounting inside electrical panels, control cabinets and automation equipment.
  • UL508 & 3-Year WarrantyCertified to UL508 (industrial control equipment), and backed by a 3-year DAPPRA warranty.
Specifications

NDR-120-24 Specifications

Complete technical specifications for the NDR-120-24 industrial DIN rail power supply.

Output

DC Output Voltage24V
Rated Current5A
Current Range0~5A
Rated Power120W
Ripple & Noise (max.)120mVp-p
Voltage Adjustment Range24~28V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±1.0%
Setup, Rise Time1200ms, 60ms/230VAC · 2500ms, 60ms/115VAC at full load
Hold Up Time (Typ.)16ms/230VAC · 10ms/115VAC at full load

Input

Voltage Range90~264VAC · 127~370VDC
Frequency Range47~63Hz
Power Factor (Typ.)PF >0.93
Efficiency (Typ.)88%
AC Current (Typ.)2.25A/115VAC · 1.3A/230VAC
Inrush Current (Typ.)20A/115VAC · 35A/230VAC
Leakage Current<1mA/240VAC

Protection

Overload105~160% rated output power · Constant current limiting · Auto-recovery
Over Voltage29~33V · Shut down output, re-power on to recover
Over TemperatureShut down output; re-power on to recover
Short CircuitProtected

Environment

Working Temperature−20 ~ +70°C (Full load up to 45°C, derating above)
Working Humidity20~95% RH non-condensing
Storage Temp., Humidity−40 ~ +85°C, 10~95% RH
Temp. Coefficient±0.03%/°C (0~45°C)
Vibration10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety & EMC

Safety StandardsUL508, TUV BS EN/EN62368-1, EAC TP TC 004
Withstand VoltageI/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC
Isolation Resistance>100M Ohms / 500VDC / 25°C / 70% RH
EMC EmissionBS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3
EMC ImmunityBS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level

Reliability & Dimensions

MTBF453,334 hrs min. MIL-HDBK-217F (25°C)
Dimensions (W×H×D)40 × 125.2 × 113.5 mm
Weight0.6 Kg
Packing0.6Kg; 20pcs/13Kg/0.9CUF
Warranty3 Years

Front Panel Controls

+V ADJOutput voltage adjustment potentiometer (24~28V)
DC OKDC output OK indicator LED
Terminal TB1Input: FG / AC-N-DC− / AC-L-DC+
Terminal TB2Output: −V (pins 1,2) / +V (pins 3,4)
Notes 1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth with a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance includes set-up tolerance, line regulation and load regulation. 4. The power supply is considered a component to be installed into a final equipment; the final equipment must be re-confirmed to meet EMC directives. 5. Derating may be needed under low input voltage. 6. The NDR-120-24 includes built-in active PFC (PF >0.93). 7. Full-load operation is specified up to 45°C ambient; derating is required above 45°C according to the derating curve.
Model Information

NDR-120-24 Model Code

The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF55.

Model Code
NDR - 120 - 24
NDRSeries prefix — DAPPRA NDR Series Slim DIN Rail Power Supply.
120 — Output WattageOutput power rating in Watts. This model provides 120W.
24 — Output VoltageNominal output voltage in VDC. This model provides 24V DC output.
Field
Meaning
Value
NDR
Series prefix
NDR
Output Wattage
Rated output power in Watts
120W
Output Voltage
Nominal DC output voltage
24V
Example: NDR-120-24 = NDR Series, 120W output power, 24V DC output voltage. DAPPRA SKU: OF55.
Dimensions

NDR-120-24 Dimensions

Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.

Mechanical Dimensions
Width (W)40 mm
Height (H)125.2 mm
Depth (D)113.5 mm
DIN Rail Slot to Top (S)35 mm
Weight0.6 Kg
Front Panel+V ADJ / DC OK
Installation Clearances
Top Clearance40 mm
Bottom Clearance20 mm
Left / Right Clearance5 mm
Adjacent Heat Source15 mm recommended
DIN RailTS35/7.5 or TS35/15
Mounting OrientationVertical only (input bottom, output top)
NDR-120-24 Mechanical Dimensions — 40 × 125.2 × 113.5 mm
Installation

NDR-120-24 Installation

The NDR-120-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.

01 / 06

Vertical Orientation Only

The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.

02 / 06

Ventilation Clearance

Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.

03 / 06

TS35 DIN Rail Mounting

Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.

04 / 06

FG Must Be Connected to PE

The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.

05 / 06

Operating Temperature Limits

The NDR-120-24 operates from −20°C to +70°C, with full-load operation specified up to 45°C ambient. Load derating is required above 45°C according to the derating curve. Do not install in high ambient temperature locations or near fire sources.

06 / 06

Pollution Degree 2 Environment

Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.

NDR-120-24 DIN Rail Installation — Vertical Orientation with Ventilation Clearance and TS35 Rail Mounting
Wiring & Terminal

NDR-120-24 Wiring & Terminal

The NDR-120-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

Terminal Pin Assignment

TB1 — Input Terminal
Pin No.Assignment
1FG (Frame Ground)
2AC/N or DC−
3AC/L or DC+
TB2 — Output Terminal
Pin No.Assignment
1, 2DC OUTPUT −V
3, 4DC OUTPUT +V

The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).

NDR-120-24 Terminal Pin Assignment — Front View with TB1, TB2, +V ADJ and DC OK

Wiring Specification

Recommended Wire
AWGRated CurrentCross-section
187 A0.8 mm²
1610 A1.3 mm²
1415 A2.1 mm²
1220 A3.3 mm²

Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.

Terminal Torque Setting
ModelI/PO/P
NDR-1207.5 kgf-cm (6.5 Lb-in)7.5 kgf-cm (6.5 Lb-in)

Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.

Fuse & Circuit Breaker (230V)
ModelFuseC16D16
NDR-120T4A/L250V510

Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.

DC Output Voltage Adjustment The NDR-120-24 includes a front-panel DC output voltage adjustment potentiometer (+V ADJ) and a DC OK indicator LED. The rated output voltage can be adjusted between 24V and 28V via the front-panel adjuster. Output current and output wattage must not exceed the rated value on its specification.
Safety & Compliance

NDR-120-24 Safety & Cautions

Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-24 power supply.

  • Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Do not remove the case of the power supply yourself.
  • Connecting both the primary and the secondary sides together is not allowed — risk of electric arcs and electric shock (danger to life).
  • Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
  • The FG (Frame Ground) must be connected to PE (Protective Earth).
  • Output current and output wattage must not exceed the rated value on its specification.
  • Before commencing any installation, maintenance or modification work, disconnect the system from supply voltage. Make sure that inadvertent connection in circuit will be impossible.
  • For continued protection against risk of fire, replace only with the same type and rating of fuse.
  • The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.

Applications

NDR-120-24 Industrial Applications

The NDR-120-24 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.

Industrial Control Systems
Factory Automation
Electromechanical Apparatus
Electrical Panels
Semiconductor Equipment
Machine Control
Process Control
Test & Measurement
Building Automation
PLC & Sensor Power
Industrial LED Lighting
Security & Access Control
Next Step

Need the NDR-120-24 for Your Application?

Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.

Support

NDR-120-24 FAQ

What is the DAPPRA NDR-120-24 used for?

The DAPPRA NDR-120-24 (SKU: OF55) is a 120W industrial DIN rail power supply that provides 24V DC at a rated current of 5A. It is designed for compatible industrial control panels, factory automation equipment, and electromechanical systems that require a 24V DC power source.

Can the NDR-120-24 supply 5A continuously?

Its rated output current is 5A at 24V DC, equivalent to 120W. Continuous full-load operation is specified up to 45°C ambient. Above 45°C, load derating is required according to the derating curve. Actual capability depends on ambient temperature, ventilation, and installation conditions.

Can I use the NDR-120-24 to power a PLC and several sensors?

It may be suitable if the PLC and sensors require 24V DC and their combined current consumption remains within the supply's 5A rating. Include startup demand and other connected loads when calculating the required capacity.

How does the NDR-120-24 differ from the NDR-120-12?

The NDR-120-24 provides 24V DC at 5A, while the NDR-120-12 provides 12V DC at 10A. Both are rated at 120W. Choose the model based on the voltage required by your equipment; the two output voltages are not interchangeable.

What is the input voltage range of the NDR-120-24?

The NDR-120-24 supports a universal single-phase AC input range of 90–264VAC at 47–63Hz and a DC input range of 127–370VDC. Follow the correct input terminal connections and verify the model datasheet before installation.

Can the output voltage of the NDR-120-24 be adjusted?

Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted from 24V to 28V DC. The output current and power must not exceed the rated limits of 5A and 120W.

What is the typical efficiency of the NDR-120-24?

The NDR-120-24 has a typical efficiency of 88%. Actual efficiency varies with input voltage and load conditions.

Does the NDR-120-24 have built-in active PFC?

Yes. The NDR-120-24 includes built-in active power factor correction (PFC) with a typical power factor greater than 0.93, helping to reduce harmonic current and improve power quality. Note that within the NDR Series, the 240W and 480W models also feature active PFC, but the NDR-120-24 itself does include this function.

What protection functions are available on the NDR-120-24?

The NDR-120-24 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection is rated at 105–160% of rated output power and uses constant-current limiting with automatic recovery after the fault is removed. Overvoltage protection is set at 29–33V and requires re-powering to recover.

Is the NDR-120-24 suitable for a compact control cabinet?

The NDR-120-24 has a 40 mm housing width. This can help with DIN rail layout in compact cabinets, but you should also account for the full unit dimensions (40 × 125.2 × 113.5 mm), wiring space, terminal access, and cooling clearance.

Does the NDR-120-24 require a cooling fan?

No. The NDR Series uses fanless natural convection cooling. Allow sufficient airflow around the power supply and follow the installation instructions for mounting orientation and clearance.

Which DIN rails are compatible with the NDR-120-24?

The NDR-120-24 supports standard TS35/7.5 and TS35/15 DIN rail mounting. Check the model's installation drawing and mounting instructions to ensure that the rail and cabinet arrangement are suitable.

Can I replace an existing 24V power supply with the NDR-120-24?

It may be suitable if the existing supply's input range, 24V output, 5A current capacity, power rating, dimensions, and terminal connections match your requirements. Check the existing unit's nameplate and load requirements before replacement.

What should I check when wiring the NDR-120-24?

Confirm the input and output terminal markings, input voltage, output polarity, wire size, and load current before connecting the unit. The protective earth connection must follow the product's wiring instructions. Disconnect the input supply before installation or maintenance.

How can I confirm compatibility and request a quotation for the NDR-120-24?

Provide the required quantity, input supply, connected equipment details, expected load, and delivery destination. DAPPRA can help confirm model suitability, current availability, pricing, lead time, technical documentation, and warranty terms.

47 ulasan untuk NDR-120-24 120W 24V 5A AC-DC Industrial DIN rail power supply

  1. Cybe****** (pemilik terverifikasi) –

    Membantu 0 0
  2. Cybe****** (pemilik terverifikasi) –

    Membantu 0 0
  3. Cybe****** (pemilik terverifikasi) –

    Membantu 1 0
  4. Syak***** (pemilik terverifikasi) –

    Membantu 0 0
  5. Soni (pemilik terverifikasi) –

    Membantu 0 0
  6. Soni (pemilik terverifikasi) –

    Membantu 0 0
  7. Hasa* (pemilik terverifikasi) –

    Membantu 0 0
  8. Bayu (pemilik terverifikasi) –

    Membantu 0 0
  9. asep (pemilik terverifikasi) –

    Membantu 0 0
  10. yana (pemilik terverifikasi) –

    Membantu 0 0

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

DAPPRA NDR-120-24 — 120W Slim DIN Rail Power Supply (24V / 5A) | SKU OF55
Overview

NDR-120-24 Overview

The DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 5A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.

The unit features a 40 mm wide metal housing, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-24 delivers reliable 24V power with 88% typical efficiency for demanding industrial loads.

Key Features

NDR-120-24 Key Features

Engineered for efficient, space-saving 24V industrial power supply applications.

  • 120W Output · 24V / 5ASingle output configuration providing 24V DC nominal output at 5A rated current (0~5A current range) with 120W rated output power.
  • Built-in Active PFCActive power factor correction with PF >0.93, reducing harmonic current and improving power quality.
  • Universal AC Input 90–264 VACFull-range single-phase AC input supports global mains voltages. Also supports 127–370 VDC input.
  • 24~28V Output AdjustmentFront-panel +V ADJ potentiometer allows the rated output voltage to be adjusted between 24V and 28V to suit the connected load.
  • 88% Typical EfficiencyThe NDR-120-24 achieves 88% typical efficiency, balancing performance with low power dissipation.
  • Slim 40 mm Metal HousingThe 40 × 125.2 × 113.5 mm metal housing enhances power dissipation and saves DIN rail space inside control cabinets.
  • Fanless Natural Convection CoolingNo fan means no dust intake, no acoustic noise and no moving parts — ideal for dusty industrial environments and silent operation.
  • Complete Protection FunctionsShort circuit, overload (105–160% rated output power, constant current limiting, auto-recovery), over voltage (29–33V) and over temperature protection are built in.
  • TS35 DIN Rail MountingDesigned for standard TS35/7.5 or TS35/15 DIN rail mounting inside electrical panels, control cabinets and automation equipment.
  • UL508 & 3-Year WarrantyCertified to UL508 (industrial control equipment), and backed by a 3-year DAPPRA warranty.
Specifications

NDR-120-24 Specifications

Complete technical specifications for the NDR-120-24 industrial DIN rail power supply.

Output

DC Output Voltage24V
Rated Current5A
Current Range0~5A
Rated Power120W
Ripple & Noise (max.)120mVp-p
Voltage Adjustment Range24~28V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±1.0%
Setup, Rise Time1200ms, 60ms/230VAC · 2500ms, 60ms/115VAC at full load
Hold Up Time (Typ.)16ms/230VAC · 10ms/115VAC at full load

Input

Voltage Range90~264VAC · 127~370VDC
Frequency Range47~63Hz
Power Factor (Typ.)PF >0.93
Efficiency (Typ.)88%
AC Current (Typ.)2.25A/115VAC · 1.3A/230VAC
Inrush Current (Typ.)20A/115VAC · 35A/230VAC
Leakage Current<1mA/240VAC

Protection

Overload105~160% rated output power · Constant current limiting · Auto-recovery
Over Voltage29~33V · Shut down output, re-power on to recover
Over TemperatureShut down output; re-power on to recover
Short CircuitProtected

Environment

Working Temperature−20 ~ +70°C (Full load up to 45°C, derating above)
Working Humidity20~95% RH non-condensing
Storage Temp., Humidity−40 ~ +85°C, 10~95% RH
Temp. Coefficient±0.03%/°C (0~45°C)
Vibration10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety & EMC

Safety StandardsUL508, TUV BS EN/EN62368-1, EAC TP TC 004
Withstand VoltageI/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC
Isolation Resistance>100M Ohms / 500VDC / 25°C / 70% RH
EMC EmissionBS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3
EMC ImmunityBS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level

Reliability & Dimensions

MTBF453,334 hrs min. MIL-HDBK-217F (25°C)
Dimensions (W×H×D)40 × 125.2 × 113.5 mm
Weight0.6 Kg
Packing0.6Kg; 20pcs/13Kg/0.9CUF
Warranty3 Years

Front Panel Controls

+V ADJOutput voltage adjustment potentiometer (24~28V)
DC OKDC output OK indicator LED
Terminal TB1Input: FG / AC-N-DC− / AC-L-DC+
Terminal TB2Output: −V (pins 1,2) / +V (pins 3,4)
Notes 1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth with a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance includes set-up tolerance, line regulation and load regulation. 4. The power supply is considered a component to be installed into a final equipment; the final equipment must be re-confirmed to meet EMC directives. 5. Derating may be needed under low input voltage. 6. The NDR-120-24 includes built-in active PFC (PF >0.93). 7. Full-load operation is specified up to 45°C ambient; derating is required above 45°C according to the derating curve.
Model Information

NDR-120-24 Model Code

The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF55.

Model Code
NDR - 120 - 24
NDRSeries prefix — DAPPRA NDR Series Slim DIN Rail Power Supply.
120 — Output WattageOutput power rating in Watts. This model provides 120W.
24 — Output VoltageNominal output voltage in VDC. This model provides 24V DC output.
Field
Meaning
Value
NDR
Series prefix
NDR
Output Wattage
Rated output power in Watts
120W
Output Voltage
Nominal DC output voltage
24V
Example: NDR-120-24 = NDR Series, 120W output power, 24V DC output voltage. DAPPRA SKU: OF55.
Dimensions

NDR-120-24 Dimensions

Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.

Mechanical Dimensions
Width (W)40 mm
Height (H)125.2 mm
Depth (D)113.5 mm
DIN Rail Slot to Top (S)35 mm
Weight0.6 Kg
Front Panel+V ADJ / DC OK
Installation Clearances
Top Clearance40 mm
Bottom Clearance20 mm
Left / Right Clearance5 mm
Adjacent Heat Source15 mm recommended
DIN RailTS35/7.5 or TS35/15
Mounting OrientationVertical only (input bottom, output top)
NDR-120-24 Mechanical Dimensions — 40 × 125.2 × 113.5 mm
Installation

NDR-120-24 Installation

The NDR-120-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.

01 / 06

Vertical Orientation Only

The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.

02 / 06

Ventilation Clearance

Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.

03 / 06

TS35 DIN Rail Mounting

Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.

04 / 06

FG Must Be Connected to PE

The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.

05 / 06

Operating Temperature Limits

The NDR-120-24 operates from −20°C to +70°C, with full-load operation specified up to 45°C ambient. Load derating is required above 45°C according to the derating curve. Do not install in high ambient temperature locations or near fire sources.

06 / 06

Pollution Degree 2 Environment

Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.

NDR-120-24 DIN Rail Installation — Vertical Orientation with Ventilation Clearance and TS35 Rail Mounting
Wiring & Terminal

NDR-120-24 Wiring & Terminal

The NDR-120-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

Terminal Pin Assignment

TB1 — Input Terminal
Pin No.Assignment
1FG (Frame Ground)
2AC/N or DC−
3AC/L or DC+
TB2 — Output Terminal
Pin No.Assignment
1, 2DC OUTPUT −V
3, 4DC OUTPUT +V

The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).

NDR-120-24 Terminal Pin Assignment — Front View with TB1, TB2, +V ADJ and DC OK

Wiring Specification

Recommended Wire
AWGRated CurrentCross-section
187 A0.8 mm²
1610 A1.3 mm²
1415 A2.1 mm²
1220 A3.3 mm²

Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.

Terminal Torque Setting
ModelI/PO/P
NDR-1207.5 kgf-cm (6.5 Lb-in)7.5 kgf-cm (6.5 Lb-in)

Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.

Fuse & Circuit Breaker (230V)
ModelFuseC16D16
NDR-120T4A/L250V510

Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.

DC Output Voltage Adjustment The NDR-120-24 includes a front-panel DC output voltage adjustment potentiometer (+V ADJ) and a DC OK indicator LED. The rated output voltage can be adjusted between 24V and 28V via the front-panel adjuster. Output current and output wattage must not exceed the rated value on its specification.
Safety & Compliance

NDR-120-24 Safety & Cautions

Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-24 power supply.

  • Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Do not remove the case of the power supply yourself.
  • Connecting both the primary and the secondary sides together is not allowed — risk of electric arcs and electric shock (danger to life).
  • Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
  • The FG (Frame Ground) must be connected to PE (Protective Earth).
  • Output current and output wattage must not exceed the rated value on its specification.
  • Before commencing any installation, maintenance or modification work, disconnect the system from supply voltage. Make sure that inadvertent connection in circuit will be impossible.
  • For continued protection against risk of fire, replace only with the same type and rating of fuse.
  • The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.

Applications

NDR-120-24 Industrial Applications

The NDR-120-24 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.

Industrial Control Systems
Factory Automation
Electromechanical Apparatus
Electrical Panels
Semiconductor Equipment
Machine Control
Process Control
Test & Measurement
Building Automation
PLC & Sensor Power
Industrial LED Lighting
Security & Access Control
Next Step

Need the NDR-120-24 for Your Application?

Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.

Support

NDR-120-24 FAQ

What is the DAPPRA NDR-120-24 used for?

The DAPPRA NDR-120-24 (SKU: OF55) is a 120W industrial DIN rail power supply that provides 24V DC at a rated current of 5A. It is designed for compatible industrial control panels, factory automation equipment, and electromechanical systems that require a 24V DC power source.

Can the NDR-120-24 supply 5A continuously?

Its rated output current is 5A at 24V DC, equivalent to 120W. Continuous full-load operation is specified up to 45°C ambient. Above 45°C, load derating is required according to the derating curve. Actual capability depends on ambient temperature, ventilation, and installation conditions.

Can I use the NDR-120-24 to power a PLC and several sensors?

It may be suitable if the PLC and sensors require 24V DC and their combined current consumption remains within the supply's 5A rating. Include startup demand and other connected loads when calculating the required capacity.

How does the NDR-120-24 differ from the NDR-120-12?

The NDR-120-24 provides 24V DC at 5A, while the NDR-120-12 provides 12V DC at 10A. Both are rated at 120W. Choose the model based on the voltage required by your equipment; the two output voltages are not interchangeable.

What is the input voltage range of the NDR-120-24?

The NDR-120-24 supports a universal single-phase AC input range of 90–264VAC at 47–63Hz and a DC input range of 127–370VDC. Follow the correct input terminal connections and verify the model datasheet before installation.

Can the output voltage of the NDR-120-24 be adjusted?

Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted from 24V to 28V DC. The output current and power must not exceed the rated limits of 5A and 120W.

What is the typical efficiency of the NDR-120-24?

The NDR-120-24 has a typical efficiency of 88%. Actual efficiency varies with input voltage and load conditions.

Does the NDR-120-24 have built-in active PFC?

Yes. The NDR-120-24 includes built-in active power factor correction (PFC) with a typical power factor greater than 0.93, helping to reduce harmonic current and improve power quality. Note that within the NDR Series, the 240W and 480W models also feature active PFC, but the NDR-120-24 itself does include this function.

What protection functions are available on the NDR-120-24?

The NDR-120-24 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection is rated at 105–160% of rated output power and uses constant-current limiting with automatic recovery after the fault is removed. Overvoltage protection is set at 29–33V and requires re-powering to recover.

Is the NDR-120-24 suitable for a compact control cabinet?

The NDR-120-24 has a 40 mm housing width. This can help with DIN rail layout in compact cabinets, but you should also account for the full unit dimensions (40 × 125.2 × 113.5 mm), wiring space, terminal access, and cooling clearance.

Does the NDR-120-24 require a cooling fan?

No. The NDR Series uses fanless natural convection cooling. Allow sufficient airflow around the power supply and follow the installation instructions for mounting orientation and clearance.

Which DIN rails are compatible with the NDR-120-24?

The NDR-120-24 supports standard TS35/7.5 and TS35/15 DIN rail mounting. Check the model's installation drawing and mounting instructions to ensure that the rail and cabinet arrangement are suitable.

Can I replace an existing 24V power supply with the NDR-120-24?

It may be suitable if the existing supply's input range, 24V output, 5A current capacity, power rating, dimensions, and terminal connections match your requirements. Check the existing unit's nameplate and load requirements before replacement.

What should I check when wiring the NDR-120-24?

Confirm the input and output terminal markings, input voltage, output polarity, wire size, and load current before connecting the unit. The protective earth connection must follow the product's wiring instructions. Disconnect the input supply before installation or maintenance.

How can I confirm compatibility and request a quotation for the NDR-120-24?

Provide the required quantity, input supply, connected equipment details, expected load, and delivery destination. DAPPRA can help confirm model suitability, current availability, pricing, lead time, technical documentation, and warranty terms.

47 ulasan untuk NDR-120-24 120W 24V 5A AC-DC Industrial DIN rail power supply

  1. Cybe****** (pemilik terverifikasi) –

    Membantu 0 0
  2. Cybe****** (pemilik terverifikasi) –

    Membantu 0 0
  3. Cybe****** (pemilik terverifikasi) –

    Membantu 1 0
  4. Syak***** (pemilik terverifikasi) –

    Membantu 0 0
  5. Soni (pemilik terverifikasi) –

    Membantu 0 0
  6. Soni (pemilik terverifikasi) –

    Membantu 0 0
  7. Hasa* (pemilik terverifikasi) –

    Membantu 0 0
  8. Bayu (pemilik terverifikasi) –

    Membantu 0 0
  9. asep (pemilik terverifikasi) –

    Membantu 0 0
  10. yana (pemilik terverifikasi) –

    Membantu 0 0

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

Pilihan lainnya untukmu

RXZE1M2C RXM2 SOCKET RELAY RXZE 1M2C PN10

Rp13,000.00 SKU:PN10

Rod Thread Pneumatic Floating Joint Cylinder JA40-14-150 KO17

Rp195,000.00 SKU:KO17