Rp325,000.00
DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply with 24V DC / 5A output and universal 90–264 VAC input. Built-in active PFC, 88% typical efficiency, slim 40 mm metal housing, fanless natural convection cooling, complete protection functions, UL508 approved, TS35 DIN rail mounting, 3-year warranty — ideal for industrial control, factory automation and electrical panels.
The DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 5A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features a 40 mm wide metal housing, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-24 delivers reliable 24V power with 88% typical efficiency for demanding industrial loads.
Engineered for efficient, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-120-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 5A |
| Current Range | 0~5A |
| Rated Power | 120W |
| Ripple & Noise (max.) | 120mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1200ms, 60ms/230VAC · 2500ms, 60ms/115VAC at full load |
| Hold Up Time (Typ.) | 16ms/230VAC · 10ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.93 |
| Efficiency (Typ.) | 88% |
| AC Current (Typ.) | 2.25A/115VAC · 1.3A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <1mA/240VAC |
| Overload | 105~160% rated output power · Constant current limiting · Auto-recovery |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; re-power on to recover |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Full load up to 45°C, derating above) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~45°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 453,334 hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 40 × 125.2 × 113.5 mm |
| Weight | 0.6 Kg |
| Packing | 0.6Kg; 20pcs/13Kg/0.9CUF |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: −V (pins 1,2) / +V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF55.
Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 40 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 113.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 0.6 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-120-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-120-24 operates from −20°C to +70°C, with full-load operation specified up to 45°C ambient. Load derating is required above 45°C according to the derating curve. Do not install in high ambient temperature locations or near fire sources.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-120-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT −V |
| 3, 4 | DC OUTPUT +V |
The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-120 | 7.5 kgf-cm (6.5 Lb-in) | 7.5 kgf-cm (6.5 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-120 | T4A/L250V | 5 | 10 |
Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-120-24 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-120-24 (SKU: OF55) is a 120W industrial DIN rail power supply that provides 24V DC at a rated current of 5A. It is designed for compatible industrial control panels, factory automation equipment, and electromechanical systems that require a 24V DC power source.
Its rated output current is 5A at 24V DC, equivalent to 120W. Continuous full-load operation is specified up to 45°C ambient. Above 45°C, load derating is required according to the derating curve. Actual capability depends on ambient temperature, ventilation, and installation conditions.
It may be suitable if the PLC and sensors require 24V DC and their combined current consumption remains within the supply's 5A rating. Include startup demand and other connected loads when calculating the required capacity.
The NDR-120-24 provides 24V DC at 5A, while the NDR-120-12 provides 12V DC at 10A. Both are rated at 120W. Choose the model based on the voltage required by your equipment; the two output voltages are not interchangeable.
The NDR-120-24 supports a universal single-phase AC input range of 90–264VAC at 47–63Hz and a DC input range of 127–370VDC. Follow the correct input terminal connections and verify the model datasheet before installation.
Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted from 24V to 28V DC. The output current and power must not exceed the rated limits of 5A and 120W.
The NDR-120-24 has a typical efficiency of 88%. Actual efficiency varies with input voltage and load conditions.
Yes. The NDR-120-24 includes built-in active power factor correction (PFC) with a typical power factor greater than 0.93, helping to reduce harmonic current and improve power quality. Note that within the NDR Series, the 240W and 480W models also feature active PFC, but the NDR-120-24 itself does include this function.
The NDR-120-24 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection is rated at 105–160% of rated output power and uses constant-current limiting with automatic recovery after the fault is removed. Overvoltage protection is set at 29–33V and requires re-powering to recover.
The NDR-120-24 has a 40 mm housing width. This can help with DIN rail layout in compact cabinets, but you should also account for the full unit dimensions (40 × 125.2 × 113.5 mm), wiring space, terminal access, and cooling clearance.
No. The NDR Series uses fanless natural convection cooling. Allow sufficient airflow around the power supply and follow the installation instructions for mounting orientation and clearance.
The NDR-120-24 supports standard TS35/7.5 and TS35/15 DIN rail mounting. Check the model's installation drawing and mounting instructions to ensure that the rail and cabinet arrangement are suitable.
It may be suitable if the existing supply's input range, 24V output, 5A current capacity, power rating, dimensions, and terminal connections match your requirements. Check the existing unit's nameplate and load requirements before replacement.
Confirm the input and output terminal markings, input voltage, output polarity, wire size, and load current before connecting the unit. The protective earth connection must follow the product's wiring instructions. Disconnect the input supply before installation or maintenance.
Provide the required quantity, input supply, connected equipment details, expected load, and delivery destination. DAPPRA can help confirm model suitability, current availability, pricing, lead time, technical documentation, and warranty terms.
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
DRM-0840-R Relay Safety Light Curtain Industrial Area Sensor
DRM-1020-R Relay Safety Light Curtain Industrial Area Sensor
DRM-0620-R Relay Safety Light Curtain Industrial Area Sensor
The DAPPRA NDR-120-24 (SKU: OF55) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 5A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features a 40 mm wide metal housing, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-24 delivers reliable 24V power with 88% typical efficiency for demanding industrial loads.
Engineered for efficient, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-120-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 5A |
| Current Range | 0~5A |
| Rated Power | 120W |
| Ripple & Noise (max.) | 120mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1200ms, 60ms/230VAC · 2500ms, 60ms/115VAC at full load |
| Hold Up Time (Typ.) | 16ms/230VAC · 10ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.93 |
| Efficiency (Typ.) | 88% |
| AC Current (Typ.) | 2.25A/115VAC · 1.3A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <1mA/240VAC |
| Overload | 105~160% rated output power · Constant current limiting · Auto-recovery |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; re-power on to recover |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Full load up to 45°C, derating above) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~45°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 453,334 hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 40 × 125.2 × 113.5 mm |
| Weight | 0.6 Kg |
| Packing | 0.6Kg; 20pcs/13Kg/0.9CUF |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: −V (pins 1,2) / +V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF55.
Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 40 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 113.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 0.6 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-120-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-120-24 operates from −20°C to +70°C, with full-load operation specified up to 45°C ambient. Load derating is required above 45°C according to the derating curve. Do not install in high ambient temperature locations or near fire sources.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-120-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT −V |
| 3, 4 | DC OUTPUT +V |
The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-120 | 7.5 kgf-cm (6.5 Lb-in) | 7.5 kgf-cm (6.5 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-120 | T4A/L250V | 5 | 10 |
Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-120-24 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-120-24 (SKU: OF55) is a 120W industrial DIN rail power supply that provides 24V DC at a rated current of 5A. It is designed for compatible industrial control panels, factory automation equipment, and electromechanical systems that require a 24V DC power source.
Its rated output current is 5A at 24V DC, equivalent to 120W. Continuous full-load operation is specified up to 45°C ambient. Above 45°C, load derating is required according to the derating curve. Actual capability depends on ambient temperature, ventilation, and installation conditions.
It may be suitable if the PLC and sensors require 24V DC and their combined current consumption remains within the supply's 5A rating. Include startup demand and other connected loads when calculating the required capacity.
The NDR-120-24 provides 24V DC at 5A, while the NDR-120-12 provides 12V DC at 10A. Both are rated at 120W. Choose the model based on the voltage required by your equipment; the two output voltages are not interchangeable.
The NDR-120-24 supports a universal single-phase AC input range of 90–264VAC at 47–63Hz and a DC input range of 127–370VDC. Follow the correct input terminal connections and verify the model datasheet before installation.
Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted from 24V to 28V DC. The output current and power must not exceed the rated limits of 5A and 120W.
The NDR-120-24 has a typical efficiency of 88%. Actual efficiency varies with input voltage and load conditions.
Yes. The NDR-120-24 includes built-in active power factor correction (PFC) with a typical power factor greater than 0.93, helping to reduce harmonic current and improve power quality. Note that within the NDR Series, the 240W and 480W models also feature active PFC, but the NDR-120-24 itself does include this function.
The NDR-120-24 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection is rated at 105–160% of rated output power and uses constant-current limiting with automatic recovery after the fault is removed. Overvoltage protection is set at 29–33V and requires re-powering to recover.
The NDR-120-24 has a 40 mm housing width. This can help with DIN rail layout in compact cabinets, but you should also account for the full unit dimensions (40 × 125.2 × 113.5 mm), wiring space, terminal access, and cooling clearance.
No. The NDR Series uses fanless natural convection cooling. Allow sufficient airflow around the power supply and follow the installation instructions for mounting orientation and clearance.
The NDR-120-24 supports standard TS35/7.5 and TS35/15 DIN rail mounting. Check the model's installation drawing and mounting instructions to ensure that the rail and cabinet arrangement are suitable.
It may be suitable if the existing supply's input range, 24V output, 5A current capacity, power rating, dimensions, and terminal connections match your requirements. Check the existing unit's nameplate and load requirements before replacement.
Confirm the input and output terminal markings, input voltage, output polarity, wire size, and load current before connecting the unit. The protective earth connection must follow the product's wiring instructions. Disconnect the input supply before installation or maintenance.
Provide the required quantity, input supply, connected equipment details, expected load, and delivery destination. DAPPRA can help confirm model suitability, current availability, pricing, lead time, technical documentation, and warranty terms.
SAKT* (pemilik terverifikasi) –
good
Part (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Anti* (pemilik terverifikasi) –
Anti* (pemilik terverifikasi) –
Sakt* (pemilik terverifikasi) –
Sakt* (pemilik terverifikasi) –
andi (pemilik terverifikasi) –
andi (pemilik terverifikasi) –
Abdu* (pemilik terverifikasi) –
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
SAKT* (pemilik terverifikasi) –
good
Part (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Anti* (pemilik terverifikasi) –
Anti* (pemilik terverifikasi) –
Sakt* (pemilik terverifikasi) –
Sakt* (pemilik terverifikasi) –
andi (pemilik terverifikasi) –
andi (pemilik terverifikasi) –
Abdu* (pemilik terverifikasi) –