Belanja minimal Rp 500.000, Gratis Ongkir!

NDR-120-12 12V 120W Industrial DIN Rail Power Supply

Rp320,000.00

VOUCHER
Diskon 5% min. belanja Rp1JT
Kode: svn56nm9 ·
🔥 10 items sold in last 3 jam
71 orang sedang melihat produk ini sekarang

DAPPRA NDR-120-12 (SKU: OF54) is a 120W single output slim industrial DIN rail power supply with 12V DC / 10A output and universal 90–264 VAC input. 87% typical efficiency, slim 40 mm metal housing, fanless natural convection cooling, complete protection functions, UL508 approved, TS35 DIN rail mounting, 3-year warranty — ideal for industrial control, factory automation and electrical panels.

12V / 10A
Output

120 W
Rated Power

90–264 VAC
Universal Input

87%
Efficiency

40 × 125 × 113 mm
Slim Housing

TS35
DIN Rail
atau

Share:

DAPPRA NDR-120-12 — 120W Slim DIN Rail Power Supply (12V / 10A) | SKU OF54
Overview

NDR-120-12 Overview

The DAPPRA NDR-120-12 (SKU: OF54) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 12V DC output at 10A rated current from a universal 90–264 VAC input or 127–370 VDC input.

The unit features a slim 40 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-12 is an economical, space-saving power supply solution for industrial control apparatus.

Key Features

NDR-120-12 Key Features

Engineered for economical, space-saving 12V industrial power supply applications.

  • 120W Output · 12V / 10ASingle output configuration providing 12V DC nominal output at 10A rated current (0~10A current range) with 120W rated output power.
  • Universal AC Input 90–264 VACFull-range single-phase AC input supports global mains voltages without external selection switches. Also supports 127–370 VDC input (DC input operation possible by connecting AC/L (+) and AC/N (−)).
  • 12~14V Output AdjustmentFront-panel +V ADJ potentiometer allows the rated output voltage to be adjusted between 12V and 14V to suit the connected load.
  • 87% Typical EfficiencyThe NDR-120-12 achieves 87% typical efficiency, reducing energy consumption and heat generation inside the control cabinet.
  • Slim 40 mm Metal HousingThe 40 × 125.2 × 113.5 mm metal housing enhances power dissipation and saves valuable DIN rail space inside control cabinets.
  • Fanless Natural Convection CoolingNo fan means no dust intake, no acoustic noise and no moving parts — ideal for dusty industrial environments and silent operation.
  • Complete Protection FunctionsShort circuit protection, overload protection (105–150% rated output power, constant current limiting, auto-recovery), over voltage protection (14–17V) and over temperature protection are built in.
  • TS35 DIN Rail MountingDesigned for standard TS35/7.5 or TS35/15 DIN rail mounting inside electrical panels, control cabinets and automation equipment.
  • UL508 & Industrial Immunity ApprovedCertified to UL508, TUV BS EN/EN62368-1 and EAC TP TC 004, and complies with BS EN/EN61000-6-2 (BS EN/EN50082-2) industrial immunity level.
  • 3-Year WarrantyEach NDR-120-12 unit is backed by a 3-year DAPPRA warranty for long-term operational confidence.
Specifications

NDR-120-12 Specifications

Complete technical specifications for the NDR-120-12 industrial DIN rail power supply.

Output

DC Output Voltage12V
Rated Current10A
Current Range0~10A
Rated Power120W
Ripple & Noise (max.)100mVp-p
Voltage Adjustment Range12~14V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±1.0%
Setup, Rise Time500ms, 30ms/230VAC · 1000ms, 30ms/115VAC at full load
Hold Up Time (Typ.)16ms/230VAC · 12ms/115VAC at full load

Input

Voltage Range90~264VAC · 127~370VDC
Frequency Range47~63Hz
Efficiency (Typ.)87%
AC Current (Typ.)2.5A/115VAC · 1.3A/230VAC
Inrush Current (Typ.)20A/115VAC · 35A/230VAC
Leakage Current<1mA/240VAC

Protection

Overload105~150% rated output power · Constant current limiting · Auto-recovery
Over Voltage14~17V
Over TemperatureShut down output voltage; re-power on to recover
Short CircuitProtected

Environment

Working Temperature−20 ~ +70°C (Refer to Derating Curve)
Working Humidity20~95% RH non-condensing
Storage Temp., Humidity−40 ~ +85°C, 10~95% RH
Temp. Coefficient±0.03%/°C (0~50°C)
Vibration10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety & EMC

Safety StandardsUL508, TUV BS EN/EN62368-1, EAC TP TC 004
Withstand VoltageI/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC
Isolation Resistance>100M Ohms / 500VDC / 25°C / 70% RH
EMC EmissionBS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3
EMC ImmunityBS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN55035 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level

Reliability & Dimensions

MTBF2632.6K hrs min. Telcordia SR-332 (Bellcore) · 466.6K hrs min. MIL-HDBK-217F (25°C)
Dimensions (W×H×D)40 × 125.2 × 113.5 mm
Weight0.6 Kg
Packing0.6Kg; 20pcs/13Kg/0.9CUF
Warranty3 Years

Front Panel Controls

+V ADJOutput voltage adjustment potentiometer (12~14V)
DC OKDC output OK indicator LED
Terminal TB1Input: FG / AC-N-DC− / AC-L-DC+
Terminal TB2Output: −V (pins 1,2) / +V (pins 3,4)
Notes 1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth with a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance includes set-up tolerance, line regulation and load regulation. 4. The power supply is considered a component to be installed into a final equipment; the final equipment must be re-confirmed to meet EMC directives. 5. Derating may be needed under low input voltage. 6. Built-in active PFC is available on NDR-240 and NDR-480 models only; the NDR-120-12 does not include active PFC.
Model Information

NDR-120-12 Model Code

The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF54.

Model Code
NDR - 120 - 12
NDRSeries prefix — DAPPRA NDR Series Slim DIN Rail Power Supply.
120 — Output WattageOutput power rating in Watts. This model provides 120W.
12 — Output VoltageNominal output voltage in VDC. This model provides 12V DC output.
Field
Meaning
Value
NDR
Series prefix
NDR
Output Wattage
Rated output power in Watts
120W
Output Voltage
Nominal DC output voltage
12V
Example: NDR-120-12 = NDR Series, 120W output power, 12V DC output voltage. DAPPRA SKU: OF54.
Dimensions

NDR-120-12 Dimensions

Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.

Mechanical Dimensions
Width (W)40 mm
Height (H)125.2 mm
Depth (D)113.5 mm
DIN Rail Slot to Top (S)35 mm
Weight0.6 Kg
Front Panel+V ADJ / DC OK
Installation Clearances
Top Clearance40 mm
Bottom Clearance20 mm
Left / Right Clearance5 mm
Adjacent Heat Source100–150 mm recommended
DIN RailTS35/7.5 or TS35/15
Mounting OrientationVertical only (input bottom, output top)
NDR-120-12 Mechanical Dimensions — 40 × 125.2 × 113.5 mm
Installation

NDR-120-12 Installation

The NDR-120-12 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.

01 / 06

Vertical Orientation Only

The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.

02 / 06

Ventilation Clearance

Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 100–150 mm clearance.

03 / 06

TS35 DIN Rail Mounting

Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.

04 / 06

FG Must Be Connected to PE

The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.

05 / 06

Operating Temperature Limits

Maximum full-load operating temperature for the NDR-120-12 is 50°C ambient. Derating is required between 50°C and 70°C. Do not install in high ambient temperature locations or near fire sources.

06 / 06

Pollution Degree 2 Environment

Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.

NDR-120-12 DIN Rail Installation — Vertical Orientation with Ventilation Clearance and TS35 Rail Mounting
Wiring & Terminal

NDR-120-12 Wiring & Terminal

The NDR-120-12 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

Terminal Pin Assignment

TB1 — Input Terminal
Pin No.Assignment
1FG (Frame Ground)
2AC/N or DC−
3AC/L or DC+
TB2 — Output Terminal
Pin No.Assignment
1, 2DC OUTPUT −V
3, 4DC OUTPUT +V

The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).

NDR-120-12 Terminal Pin Assignment — Front View with TB1, TB2, +V ADJ and DC OK

Wiring Specification

Recommended Wire
AWGRated CurrentCross-section
187 A0.8 mm²
1610 A1.3 mm²
1415 A2.1 mm²
1220 A3.3 mm²

Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.

Terminal Torque Setting
ModelI/PO/P
NDR-1207.5 kgf-cm (6.5 Lb-in)7.5 kgf-cm (6.5 Lb-in)

Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.

Fuse & Circuit Breaker (230V)
ModelFuseC16D16
NDR-120T4A/L250V510

Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.

DC Output Voltage Adjustment The NDR-120-12 includes a front-panel DC output voltage adjustment potentiometer (+V ADJ) and a DC OK indicator LED. The rated output voltage can be adjusted between 12V and 14V via the front-panel adjuster. Output current and output wattage must not exceed the rated value on its specification.
Safety & Compliance

NDR-120-12 Safety & Cautions

Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-12 power supply.

  • Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Do not remove the case of the power supply yourself.
  • Connecting both the primary and the secondary sides together is not allowed — risk of electric arcs and electric shock (danger to life).
  • Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
  • The FG (Frame Ground) must be connected to PE (Protective Earth).
  • Output current and output wattage must not exceed the rated value on its specification.
  • Before commencing any installation, maintenance or modification work, disconnect the system from supply voltage. Make sure that inadvertent connection in circuit will be impossible.
  • For continued protection against risk of fire, replace only with the same type and rating of fuse.
  • The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.

Applications

NDR-120-12 Industrial Applications

The NDR-120-12 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.

Industrial Control Systems
Factory Automation
Electromechanical Apparatus
Electrical Panels
Semiconductor Equipment
Machine Control
Process Control
Test & Measurement
Building Automation
PLC & Sensor Power
Industrial LED Lighting
Security & Access Control
Next Step

Need the NDR-120-12 for Your Application?

Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.

Support

NDR-120-12 FAQ

What is the DAPPRA NDR-120-12 DIN rail power supply?

The DAPPRA NDR-120-12 (SKU: OF54) is a 120W single-output industrial DIN rail power supply that delivers 12V DC at a rated current of 10A. It features a slim 40 mm metal housing, fanless natural convection cooling, and built-in protection functions. It is designed for industrial control panels, factory automation, and electromechanical equipment.

What are the output voltage, current, and power ratings?

The NDR-120-12 provides a nominal 12V DC output, a rated output current of 10A, and a rated output power of 120W. The output voltage can be adjusted from 12V to 14V using the front-panel +V ADJ potentiometer. The output current and total output power must remain within the unit's rated limits.

What is the input voltage range of the NDR-120-12?

The NDR-120-12 supports a single-phase AC input range of 90–264VAC at 47–63Hz. It also supports a DC input range of 127–370VDC. Confirm the input source and follow the official wiring instructions before installation.

How many devices can the NDR-120-12 power?

The number of devices depends on their combined current consumption, startup demand, and operating conditions. The power supply is rated for up to 10A at its nominal 12V output, equivalent to 120W. Calculate the total load and allow for suitable operating margin before connecting multiple devices.

Is the NDR-120-12 suitable for PLCs, sensors, and industrial control equipment?

Yes, it can be considered for equipment requiring a compatible 12V DC supply, including suitable industrial control devices, sensors, and electronic equipment. Check each device's required voltage, current consumption, startup demand, and allowable ripple before selecting the power supply.

What is the efficiency of the NDR-120-12?

The NDR-120-12 has a typical efficiency of 87%. Actual efficiency varies with input voltage and load conditions.

Does the NDR-120-12 have active PFC?

No. The NDR-120-12 does not include built-in active power factor correction (PFC). According to the product specifications, it meets BS EN/EN61000-3-2 Class A harmonic current requirements. Active PFC is available on the NDR-240 and NDR-480 models listed in the NDR Series documentation.

What protection functions are built into the NDR-120-12?

The NDR-120-12 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection uses constant-current limiting with automatic recovery. Overtemperature protection shuts down the output, and power must be cycled to restore operation after the unit has cooled and the cause has been addressed.

Can the NDR-120-12 operate continuously in an industrial control cabinet?

It is designed for industrial power applications. The published operating temperature range is −20°C to +70°C, with full-load operation specified up to 50°C ambient. Load derating is required above 50°C. Proper ventilation, installation orientation, and load sizing are important for reliable operation.

Does the NDR-120-12 require a cooling fan?

No. The NDR-120-12 uses fanless natural convection cooling. To support proper heat dissipation, install the unit vertically and maintain the recommended clearances: 40 mm above, 20 mm below, and 5 mm on each side. Keep greater separation from adjacent heat sources as specified in the installation guide.

What are the dimensions and weight of the NDR-120-12?

The NDR-120-12 measures 40 × 125.2 × 113.5 mm (W × H × D) and weighs approximately 0.6 kg. Its slim housing helps save space in industrial control cabinets. Check the installation drawing and required ventilation clearances before mounting.

Is the NDR-120-12 compatible with standard DIN rails?

Yes. The NDR-120-12 is designed for TS35/7.5 and TS35/15 DIN rail mounting. The specified mounting orientation is vertical, with the input terminals at the bottom and output terminals at the top. Follow the installation guide for mounting and wiring.

Can the NDR-120-12 replace an existing 12V power supply?

It may be suitable as a replacement if the electrical and mechanical requirements match. Before replacing an existing unit, check the input voltage range, output voltage, rated current, power, dimensions, terminal connections, and cooling requirements. Contact DAPPRA with the original model number or a clear nameplate photo for assistance with compatibility checks.

What certifications and compliance standards apply to the NDR-120-12?

The supplied product documentation lists UL508, TUV BS EN/EN62368-1, and EAC TP TC 004, together with industrial immunity and EMC standards. Please request the applicable certificates and confirm their validity and model coverage for your destination market before placing an order.

What is the warranty period, and how can I request a quotation?

The product page specifies a 3-year warranty for the NDR-120-12. For a quotation, please provide the required quantity, delivery destination, and any technical or certification requirements. Contact DAPPRA to confirm current availability, lead time, pricing, and the applicable warranty terms.

Ulasan

Belum ada ulasan.

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

DAPPRA NDR-120-12 — 120W Slim DIN Rail Power Supply (12V / 10A) | SKU OF54
Overview

NDR-120-12 Overview

The DAPPRA NDR-120-12 (SKU: OF54) is a 120W single output slim industrial DIN rail power supply designed for industrial control, factory automation and electromechanical applications. It provides a stable 12V DC output at 10A rated current from a universal 90–264 VAC input or 127–370 VDC input.

The unit features a slim 40 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-120-12 is an economical, space-saving power supply solution for industrial control apparatus.

Key Features

NDR-120-12 Key Features

Engineered for economical, space-saving 12V industrial power supply applications.

  • 120W Output · 12V / 10ASingle output configuration providing 12V DC nominal output at 10A rated current (0~10A current range) with 120W rated output power.
  • Universal AC Input 90–264 VACFull-range single-phase AC input supports global mains voltages without external selection switches. Also supports 127–370 VDC input (DC input operation possible by connecting AC/L (+) and AC/N (−)).
  • 12~14V Output AdjustmentFront-panel +V ADJ potentiometer allows the rated output voltage to be adjusted between 12V and 14V to suit the connected load.
  • 87% Typical EfficiencyThe NDR-120-12 achieves 87% typical efficiency, reducing energy consumption and heat generation inside the control cabinet.
  • Slim 40 mm Metal HousingThe 40 × 125.2 × 113.5 mm metal housing enhances power dissipation and saves valuable DIN rail space inside control cabinets.
  • Fanless Natural Convection CoolingNo fan means no dust intake, no acoustic noise and no moving parts — ideal for dusty industrial environments and silent operation.
  • Complete Protection FunctionsShort circuit protection, overload protection (105–150% rated output power, constant current limiting, auto-recovery), over voltage protection (14–17V) and over temperature protection are built in.
  • TS35 DIN Rail MountingDesigned for standard TS35/7.5 or TS35/15 DIN rail mounting inside electrical panels, control cabinets and automation equipment.
  • UL508 & Industrial Immunity ApprovedCertified to UL508, TUV BS EN/EN62368-1 and EAC TP TC 004, and complies with BS EN/EN61000-6-2 (BS EN/EN50082-2) industrial immunity level.
  • 3-Year WarrantyEach NDR-120-12 unit is backed by a 3-year DAPPRA warranty for long-term operational confidence.
Specifications

NDR-120-12 Specifications

Complete technical specifications for the NDR-120-12 industrial DIN rail power supply.

Output

DC Output Voltage12V
Rated Current10A
Current Range0~10A
Rated Power120W
Ripple & Noise (max.)100mVp-p
Voltage Adjustment Range12~14V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±1.0%
Setup, Rise Time500ms, 30ms/230VAC · 1000ms, 30ms/115VAC at full load
Hold Up Time (Typ.)16ms/230VAC · 12ms/115VAC at full load

Input

Voltage Range90~264VAC · 127~370VDC
Frequency Range47~63Hz
Efficiency (Typ.)87%
AC Current (Typ.)2.5A/115VAC · 1.3A/230VAC
Inrush Current (Typ.)20A/115VAC · 35A/230VAC
Leakage Current<1mA/240VAC

Protection

Overload105~150% rated output power · Constant current limiting · Auto-recovery
Over Voltage14~17V
Over TemperatureShut down output voltage; re-power on to recover
Short CircuitProtected

Environment

Working Temperature−20 ~ +70°C (Refer to Derating Curve)
Working Humidity20~95% RH non-condensing
Storage Temp., Humidity−40 ~ +85°C, 10~95% RH
Temp. Coefficient±0.03%/°C (0~50°C)
Vibration10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

Safety & EMC

Safety StandardsUL508, TUV BS EN/EN62368-1, EAC TP TC 004
Withstand VoltageI/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC
Isolation Resistance>100M Ohms / 500VDC / 25°C / 70% RH
EMC EmissionBS EN/EN55032 (CISPR32) Class A · BS EN/EN61000-3-2,-3
EMC ImmunityBS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN55035 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level

Reliability & Dimensions

MTBF2632.6K hrs min. Telcordia SR-332 (Bellcore) · 466.6K hrs min. MIL-HDBK-217F (25°C)
Dimensions (W×H×D)40 × 125.2 × 113.5 mm
Weight0.6 Kg
Packing0.6Kg; 20pcs/13Kg/0.9CUF
Warranty3 Years

Front Panel Controls

+V ADJOutput voltage adjustment potentiometer (12~14V)
DC OKDC output OK indicator LED
Terminal TB1Input: FG / AC-N-DC− / AC-L-DC+
Terminal TB2Output: −V (pins 1,2) / +V (pins 3,4)
Notes 1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth with a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance includes set-up tolerance, line regulation and load regulation. 4. The power supply is considered a component to be installed into a final equipment; the final equipment must be re-confirmed to meet EMC directives. 5. Derating may be needed under low input voltage. 6. Built-in active PFC is available on NDR-240 and NDR-480 models only; the NDR-120-12 does not include active PFC.
Model Information

NDR-120-12 Model Code

The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF54.

Model Code
NDR - 120 - 12
NDRSeries prefix — DAPPRA NDR Series Slim DIN Rail Power Supply.
120 — Output WattageOutput power rating in Watts. This model provides 120W.
12 — Output VoltageNominal output voltage in VDC. This model provides 12V DC output.
Field
Meaning
Value
NDR
Series prefix
NDR
Output Wattage
Rated output power in Watts
120W
Output Voltage
Nominal DC output voltage
12V
Example: NDR-120-12 = NDR Series, 120W output power, 12V DC output voltage. DAPPRA SKU: OF54.
Dimensions

NDR-120-12 Dimensions

Slim 40 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.

Mechanical Dimensions
Width (W)40 mm
Height (H)125.2 mm
Depth (D)113.5 mm
DIN Rail Slot to Top (S)35 mm
Weight0.6 Kg
Front Panel+V ADJ / DC OK
Installation Clearances
Top Clearance40 mm
Bottom Clearance20 mm
Left / Right Clearance5 mm
Adjacent Heat Source100–150 mm recommended
DIN RailTS35/7.5 or TS35/15
Mounting OrientationVertical only (input bottom, output top)
NDR-120-12 Mechanical Dimensions — 40 × 125.2 × 113.5 mm
Installation

NDR-120-12 Installation

The NDR-120-12 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.

01 / 06

Vertical Orientation Only

The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.

02 / 06

Ventilation Clearance

Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 100–150 mm clearance.

03 / 06

TS35 DIN Rail Mounting

Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.

04 / 06

FG Must Be Connected to PE

The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.

05 / 06

Operating Temperature Limits

Maximum full-load operating temperature for the NDR-120-12 is 50°C ambient. Derating is required between 50°C and 70°C. Do not install in high ambient temperature locations or near fire sources.

06 / 06

Pollution Degree 2 Environment

Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.

NDR-120-12 DIN Rail Installation — Vertical Orientation with Ventilation Clearance and TS35 Rail Mounting
Wiring & Terminal

NDR-120-12 Wiring & Terminal

The NDR-120-12 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

Terminal Pin Assignment

TB1 — Input Terminal
Pin No.Assignment
1FG (Frame Ground)
2AC/N or DC−
3AC/L or DC+
TB2 — Output Terminal
Pin No.Assignment
1, 2DC OUTPUT −V
3, 4DC OUTPUT +V

The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).

NDR-120-12 Terminal Pin Assignment — Front View with TB1, TB2, +V ADJ and DC OK

Wiring Specification

Recommended Wire
AWGRated CurrentCross-section
187 A0.8 mm²
1610 A1.3 mm²
1415 A2.1 mm²
1220 A3.3 mm²

Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.

Terminal Torque Setting
ModelI/PO/P
NDR-1207.5 kgf-cm (6.5 Lb-in)7.5 kgf-cm (6.5 Lb-in)

Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.

Fuse & Circuit Breaker (230V)
ModelFuseC16D16
NDR-120T4A/L250V510

Maximum number of NDR-120 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.

DC Output Voltage Adjustment The NDR-120-12 includes a front-panel DC output voltage adjustment potentiometer (+V ADJ) and a DC OK indicator LED. The rated output voltage can be adjusted between 12V and 14V via the front-panel adjuster. Output current and output wattage must not exceed the rated value on its specification.
Safety & Compliance

NDR-120-12 Safety & Cautions

Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-120-12 power supply.

  • Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Do not remove the case of the power supply yourself.
  • Connecting both the primary and the secondary sides together is not allowed — risk of electric arcs and electric shock (danger to life).
  • Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
  • The FG (Frame Ground) must be connected to PE (Protective Earth).
  • Output current and output wattage must not exceed the rated value on its specification.
  • Before commencing any installation, maintenance or modification work, disconnect the system from supply voltage. Make sure that inadvertent connection in circuit will be impossible.
  • For continued protection against risk of fire, replace only with the same type and rating of fuse.
  • The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.

Applications

NDR-120-12 Industrial Applications

The NDR-120-12 is suitable for industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.

Industrial Control Systems
Factory Automation
Electromechanical Apparatus
Electrical Panels
Semiconductor Equipment
Machine Control
Process Control
Test & Measurement
Building Automation
PLC & Sensor Power
Industrial LED Lighting
Security & Access Control
Next Step

Need the NDR-120-12 for Your Application?

Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.

Support

NDR-120-12 FAQ

What is the DAPPRA NDR-120-12 DIN rail power supply?

The DAPPRA NDR-120-12 (SKU: OF54) is a 120W single-output industrial DIN rail power supply that delivers 12V DC at a rated current of 10A. It features a slim 40 mm metal housing, fanless natural convection cooling, and built-in protection functions. It is designed for industrial control panels, factory automation, and electromechanical equipment.

What are the output voltage, current, and power ratings?

The NDR-120-12 provides a nominal 12V DC output, a rated output current of 10A, and a rated output power of 120W. The output voltage can be adjusted from 12V to 14V using the front-panel +V ADJ potentiometer. The output current and total output power must remain within the unit's rated limits.

What is the input voltage range of the NDR-120-12?

The NDR-120-12 supports a single-phase AC input range of 90–264VAC at 47–63Hz. It also supports a DC input range of 127–370VDC. Confirm the input source and follow the official wiring instructions before installation.

How many devices can the NDR-120-12 power?

The number of devices depends on their combined current consumption, startup demand, and operating conditions. The power supply is rated for up to 10A at its nominal 12V output, equivalent to 120W. Calculate the total load and allow for suitable operating margin before connecting multiple devices.

Is the NDR-120-12 suitable for PLCs, sensors, and industrial control equipment?

Yes, it can be considered for equipment requiring a compatible 12V DC supply, including suitable industrial control devices, sensors, and electronic equipment. Check each device's required voltage, current consumption, startup demand, and allowable ripple before selecting the power supply.

What is the efficiency of the NDR-120-12?

The NDR-120-12 has a typical efficiency of 87%. Actual efficiency varies with input voltage and load conditions.

Does the NDR-120-12 have active PFC?

No. The NDR-120-12 does not include built-in active power factor correction (PFC). According to the product specifications, it meets BS EN/EN61000-3-2 Class A harmonic current requirements. Active PFC is available on the NDR-240 and NDR-480 models listed in the NDR Series documentation.

What protection functions are built into the NDR-120-12?

The NDR-120-12 includes short-circuit, overload, overvoltage, and overtemperature protection. Overload protection uses constant-current limiting with automatic recovery. Overtemperature protection shuts down the output, and power must be cycled to restore operation after the unit has cooled and the cause has been addressed.

Can the NDR-120-12 operate continuously in an industrial control cabinet?

It is designed for industrial power applications. The published operating temperature range is −20°C to +70°C, with full-load operation specified up to 50°C ambient. Load derating is required above 50°C. Proper ventilation, installation orientation, and load sizing are important for reliable operation.

Does the NDR-120-12 require a cooling fan?

No. The NDR-120-12 uses fanless natural convection cooling. To support proper heat dissipation, install the unit vertically and maintain the recommended clearances: 40 mm above, 20 mm below, and 5 mm on each side. Keep greater separation from adjacent heat sources as specified in the installation guide.

What are the dimensions and weight of the NDR-120-12?

The NDR-120-12 measures 40 × 125.2 × 113.5 mm (W × H × D) and weighs approximately 0.6 kg. Its slim housing helps save space in industrial control cabinets. Check the installation drawing and required ventilation clearances before mounting.

Is the NDR-120-12 compatible with standard DIN rails?

Yes. The NDR-120-12 is designed for TS35/7.5 and TS35/15 DIN rail mounting. The specified mounting orientation is vertical, with the input terminals at the bottom and output terminals at the top. Follow the installation guide for mounting and wiring.

Can the NDR-120-12 replace an existing 12V power supply?

It may be suitable as a replacement if the electrical and mechanical requirements match. Before replacing an existing unit, check the input voltage range, output voltage, rated current, power, dimensions, terminal connections, and cooling requirements. Contact DAPPRA with the original model number or a clear nameplate photo for assistance with compatibility checks.

What certifications and compliance standards apply to the NDR-120-12?

The supplied product documentation lists UL508, TUV BS EN/EN62368-1, and EAC TP TC 004, together with industrial immunity and EMC standards. Please request the applicable certificates and confirm their validity and model coverage for your destination market before placing an order.

What is the warranty period, and how can I request a quotation?

The product page specifies a 3-year warranty for the NDR-120-12. For a quotation, please provide the required quantity, delivery destination, and any technical or certification requirements. Contact DAPPRA to confirm current availability, lead time, pricing, and the applicable warranty terms.

Ulasan

Belum ada ulasan.

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

Pilihan lainnya untukmu

PLC Q Series 0.5m extension rack cable QC05B SF36

Rp430,000.00 SKU:SF36