Rp190,000.00
The DAPPRA DR-60-24 (SKU: PM23) is a 60W single-output Class II double-insulated DIN rail power supply in the DR Series. It provides a stable 24V DC output at 2.5A from a universal 85–264 VAC input or 120–370 VDC input, with 84% typical efficiency and a ±10% output adjustment range of 21.6–28.8V.
Sharing the same 78 mm wide plastic step-shape housing as the DR-30, the DR-60-24 doubles the output current while maintaining Class II double insulation — no FG/PE terminal is provided and no grounding connection is required. This makes it well-suited to building automation, household control and general industrial control cabinets where a protective earth conductor may not be available. Protection includes short circuit, overload (105–150% constant current limiting, auto-recovery) and over-voltage (28.8–33.6V, shut-down and re-power). Ripple is 150mVp-p and no-load consumption is below 0.5W.
Engineered for 24V loads up to 2.5A in Class II building and industrial control cabinets.
| DC Voltage | 24V |
| Rated Current | 2.5A |
| Current Range | 0–2.5A |
| Rated Power | 60W |
| Ripple | 150mVp-p |
| Adjustment | 21.6–28.8V |
| Tolerance | ±1.0% |
| Voltage | 85–264VAC · 120–370VDC |
| Efficiency | 84% |
| No-Load | <0.5W |
| AC Current (Typ.) | 1.5A/115VAC · 0.9A/230VAC |
| Overload | 105–150% · Constant current limiting · Auto-recovery |
| Over Voltage | 28.8–33.6V · Shut down, re-power to recover |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +60°C (Derating above +40°C) |
| Working Humidity | 20–90% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10–95% RH |
| Vibration | 10–500Hz, 2G 10min./1cycle, 60min. each axis |
| Safety Standards | UL508, TUV EN60950-1 |
| Withstand Voltage | I/P-O/P: 3KVAC |
| Isolation Class | Class II (no FG/PE) |
| EMC Emission | EN55022 Class B |
| EMC Immunity | EN61000-6-2 industrial immunity |
| Dimensions (W×H×D) | 78 × 93 × 56 mm |
| Weight | Approx. 0.3 kg |
| Housing | Plastic, step-shape, Class II |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (21.6–28.8V) |
| LED | Power-on indicator |
| Isolation | Class II (no PE required) |
78 mm step-shape plastic housing, 93 mm height. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 78 mm |
| Height (H) | 93 mm |
| Depth (D) | 56 mm |
| Weight | Approx. 0.3 kg |
| Housing | Plastic, Class II |
| Top/Bottom | 40 / 20 mm |
| Sides | 5 mm |
| DIN Rail | TS35/7.5 or 15 |
| Adjacent Heat Source | 100–150 mm recommended |
Input terminals on the right, output terminals on the left. Other orientations are not allowed for adequate cooling.
5 mm sides, 40 mm top, 20 mm bottom. 100–150 mm from heat sources.
TS35/7.5 or 15. Tilt, fit, slide, lock, check.
No grounding required. Plastic housing prevents user contact with hazards.
−20 to +60°C, derate above +40°C.
Dry, ventilated control cabinet.
| Pin | Assignment |
|---|---|
| 1 | AC/N |
| 2 | AC/L |
| Pin | Assignment |
|---|---|
| +V | DC OUTPUT +V |
| −V | DC OUTPUT −V |
| LED | Power-on indicator |
| ADJ | +V ADJ potentiometer |
Class II model — no FG/PE terminal. Verify terminal labels before wiring. Use copper wire rated at least 80°C, such as UL1007.
Contact DAPPRA Automation — or explore the full DR Series.
The DAPPRA DR-60-24 (SKU: PM23) is a 60W single-output Class II double-insulated DIN rail power supply providing 24V DC at 2.5A. It features a 78 mm wide plastic step-shape housing, universal 85–264VAC input, 84% typical efficiency, and requires no grounding connection.
85–264VAC (single phase) or 120–370VDC. Suitable for global mains voltages without external selection switches.
Yes. Class II double insulated with a plastic step-shape housing. No FG/PE terminal and no grounding connection required, simplifying installation in building automation and household control systems.
21.6–28.8V via the front-panel +V ADJ potentiometer (±10% of 24V). Sufficient for voltage-drop compensation without exceeding the tolerance of most 24V industrial devices.
Approximately 28.8–33.6V (120–140% of 24V). The output shuts down and requires re-powering to recover.
105–150% rated output power, constant current limiting, auto-recovery after fault removed.
Maximum 150mVp-p at 20MHz bandwidth with 0.1μF & 47μF parallel capacitor.
78 × 93 × 56 mm (W × H × D), approximately 0.3 kg. The 78 mm width is shared with the DR-30 model.
TB1 (Input): AC/N and AC/L. TB2 (Output): DC OUTPUT +V, DC OUTPUT −V, LED indicator, and +V ADJ. No FG/PE terminal (Class II). Verify terminal labels before wiring.
Below 0.5W, supporting energy-efficient standby operation.
−20°C to +60°C with free air convection cooling. Derating is required above +40°C ambient.
Yes. Class II double insulated — no protective earth connection required. The plastic housing prevents user contact with electrical hazards.
UL508 (industrial control equipment) and TUV EN60950-1. Complies with EN61000-6-2 industrial immunity, EN55022 Class B EMC emission and EN61000-3-2 harmonic current standards.
DR-60-24 doubles output current to 2.5A (60W vs 36W) and shares the same 78 mm housing. Efficiency rises from 83% to 84%. Choose DR-60-24 when the 24V load exceeds 1.5A but stays within 2.5A.
Yes, if combined steady-state current stays within 2.5A (60W). Add worst-case relay pull-in current to the sensor draw and verify the total before connecting. If approaching 2.5A, step up to the DR-75-24 (3.2A).
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
DRM-0840-R Relay Safety Light Curtain Industrial Area Sensor
DRM-1020-R Relay Safety Light Curtain Industrial Area Sensor
DRM-0620-R Relay Safety Light Curtain Industrial Area Sensor
The DAPPRA DR-60-24 (SKU: PM23) is a 60W single-output Class II double-insulated DIN rail power supply in the DR Series. It provides a stable 24V DC output at 2.5A from a universal 85–264 VAC input or 120–370 VDC input, with 84% typical efficiency and a ±10% output adjustment range of 21.6–28.8V.
Sharing the same 78 mm wide plastic step-shape housing as the DR-30, the DR-60-24 doubles the output current while maintaining Class II double insulation — no FG/PE terminal is provided and no grounding connection is required. This makes it well-suited to building automation, household control and general industrial control cabinets where a protective earth conductor may not be available. Protection includes short circuit, overload (105–150% constant current limiting, auto-recovery) and over-voltage (28.8–33.6V, shut-down and re-power). Ripple is 150mVp-p and no-load consumption is below 0.5W.
Engineered for 24V loads up to 2.5A in Class II building and industrial control cabinets.
| DC Voltage | 24V |
| Rated Current | 2.5A |
| Current Range | 0–2.5A |
| Rated Power | 60W |
| Ripple | 150mVp-p |
| Adjustment | 21.6–28.8V |
| Tolerance | ±1.0% |
| Voltage | 85–264VAC · 120–370VDC |
| Efficiency | 84% |
| No-Load | <0.5W |
| AC Current (Typ.) | 1.5A/115VAC · 0.9A/230VAC |
| Overload | 105–150% · Constant current limiting · Auto-recovery |
| Over Voltage | 28.8–33.6V · Shut down, re-power to recover |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +60°C (Derating above +40°C) |
| Working Humidity | 20–90% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10–95% RH |
| Vibration | 10–500Hz, 2G 10min./1cycle, 60min. each axis |
| Safety Standards | UL508, TUV EN60950-1 |
| Withstand Voltage | I/P-O/P: 3KVAC |
| Isolation Class | Class II (no FG/PE) |
| EMC Emission | EN55022 Class B |
| EMC Immunity | EN61000-6-2 industrial immunity |
| Dimensions (W×H×D) | 78 × 93 × 56 mm |
| Weight | Approx. 0.3 kg |
| Housing | Plastic, step-shape, Class II |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (21.6–28.8V) |
| LED | Power-on indicator |
| Isolation | Class II (no PE required) |
78 mm step-shape plastic housing, 93 mm height. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 78 mm |
| Height (H) | 93 mm |
| Depth (D) | 56 mm |
| Weight | Approx. 0.3 kg |
| Housing | Plastic, Class II |
| Top/Bottom | 40 / 20 mm |
| Sides | 5 mm |
| DIN Rail | TS35/7.5 or 15 |
| Adjacent Heat Source | 100–150 mm recommended |
Input terminals on the right, output terminals on the left. Other orientations are not allowed for adequate cooling.
5 mm sides, 40 mm top, 20 mm bottom. 100–150 mm from heat sources.
TS35/7.5 or 15. Tilt, fit, slide, lock, check.
No grounding required. Plastic housing prevents user contact with hazards.
−20 to +60°C, derate above +40°C.
Dry, ventilated control cabinet.
| Pin | Assignment |
|---|---|
| 1 | AC/N |
| 2 | AC/L |
| Pin | Assignment |
|---|---|
| +V | DC OUTPUT +V |
| −V | DC OUTPUT −V |
| LED | Power-on indicator |
| ADJ | +V ADJ potentiometer |
Class II model — no FG/PE terminal. Verify terminal labels before wiring. Use copper wire rated at least 80°C, such as UL1007.
Contact DAPPRA Automation — or explore the full DR Series.
The DAPPRA DR-60-24 (SKU: PM23) is a 60W single-output Class II double-insulated DIN rail power supply providing 24V DC at 2.5A. It features a 78 mm wide plastic step-shape housing, universal 85–264VAC input, 84% typical efficiency, and requires no grounding connection.
85–264VAC (single phase) or 120–370VDC. Suitable for global mains voltages without external selection switches.
Yes. Class II double insulated with a plastic step-shape housing. No FG/PE terminal and no grounding connection required, simplifying installation in building automation and household control systems.
21.6–28.8V via the front-panel +V ADJ potentiometer (±10% of 24V). Sufficient for voltage-drop compensation without exceeding the tolerance of most 24V industrial devices.
Approximately 28.8–33.6V (120–140% of 24V). The output shuts down and requires re-powering to recover.
105–150% rated output power, constant current limiting, auto-recovery after fault removed.
Maximum 150mVp-p at 20MHz bandwidth with 0.1μF & 47μF parallel capacitor.
78 × 93 × 56 mm (W × H × D), approximately 0.3 kg. The 78 mm width is shared with the DR-30 model.
TB1 (Input): AC/N and AC/L. TB2 (Output): DC OUTPUT +V, DC OUTPUT −V, LED indicator, and +V ADJ. No FG/PE terminal (Class II). Verify terminal labels before wiring.
Below 0.5W, supporting energy-efficient standby operation.
−20°C to +60°C with free air convection cooling. Derating is required above +40°C ambient.
Yes. Class II double insulated — no protective earth connection required. The plastic housing prevents user contact with electrical hazards.
UL508 (industrial control equipment) and TUV EN60950-1. Complies with EN61000-6-2 industrial immunity, EN55022 Class B EMC emission and EN61000-3-2 harmonic current standards.
DR-60-24 doubles output current to 2.5A (60W vs 36W) and shares the same 78 mm housing. Efficiency rises from 83% to 84%. Choose DR-60-24 when the 24V load exceeds 1.5A but stays within 2.5A.
Yes, if combined steady-state current stays within 2.5A (60W). Add worst-case relay pull-in current to the sensor draw and verify the total before connecting. If approaching 2.5A, step up to the DR-75-24 (3.2A).
Susi** (pemilik terverifikasi) –
Zeky (pemilik terverifikasi) –
Hend** (pemilik terverifikasi) –
noto (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Heri (pemilik terverifikasi) –
Ardh* (pemilik terverifikasi) –
Ardh* (pemilik terverifikasi) –
Ridw** (pemilik terverifikasi) –
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
Susi** (pemilik terverifikasi) –
Zeky (pemilik terverifikasi) –
Hend** (pemilik terverifikasi) –
noto (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Part (pemilik terverifikasi) –
Heri (pemilik terverifikasi) –
Ardh* (pemilik terverifikasi) –
Ardh* (pemilik terverifikasi) –
Ridw** (pemilik terverifikasi) –