DAPPRA NDR-480-24 (SKU: OF59) is a 480W single output slim industrial DIN rail power supply with 24V DC / 20A output and universal 90–264 VAC input. Built-in active PFC, 92.5% typical efficiency, slim 85.5 mm metal housing, fanless natural convection cooling, complete protection functions, UL508 approved, TS35 DIN rail mounting, 3-year warranty — ideal for high-power industrial control, factory automation and electrical panels.
The DAPPRA NDR-480-24 (SKU: OF59) is a 480W single output slim industrial DIN rail power supply designed for higher-power industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 20A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features an 85.5 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting with shutdown), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-480-24 delivers a high-efficiency 92.5% power solution for demanding industrial loads.
Engineered for high-power, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-480-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 20A |
| Current Range | 0~20A |
| Rated Power | 480W |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1500ms, 100ms/230VAC · 3000ms, 100ms/115VAC at full load |
| Hold Up Time (Typ.) | 16ms/230VAC · 16ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.98/115VAC · PF >0.94/230VAC at full load |
| Efficiency (Typ.) | 92.5% |
| AC Current (Typ.) | 4.8A/115VAC · 2.4A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <2mA/240VAC |
| Overload | 105~130% rated output power · Constant current limiting · Shut down after ~3s, re-power on to recover |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; auto-recovery after temperature falls |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Refer to Derating Curve) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~50°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class B · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 1041.6K hrs min. Telcordia SR-332 (Bellcore) · 146.8K hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 85.5 × 125.2 × 128.5 mm |
| Weight | 1.5 Kg |
| Packing | 1.5Kg; 8pcs/13Kg/0.9CUFT |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: +V (pins 1,2) / −V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF59.
Slim 85.5 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 85.5 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 128.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 1.5 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-480-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-480-24 operates from −20°C to +70°C, with full-load operation specified up to approximately 50°C ambient. Load derating is required above this temperature according to the derating curve. Do not install in high ambient temperature locations or near fire sources.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-480-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT +V |
| 3, 4 | DC OUTPUT −V |
Note: The NDR-480 TB2 pin order is reversed compared to NDR-75 / 120 / 240. Verify the terminal label before wiring.
The FG pin must be connected to PE (Protective Earth). Both +V pins (1, 2) and both −V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact.
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-480 | 10.35 kgf-cm (9 Lb-in) | 10.35 kgf-cm (9 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-480 | T8A/L250V | 3 | 5 |
Maximum number of NDR-480 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-480-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-480-24 is suitable for higher-power industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-480-24 (SKU: OF59) is a 480W single-output industrial DIN rail power supply designed for industrial control panels, factory automation and electromechanical equipment. It provides 24V DC output at 20A and features built-in active PFC, fanless cooling and multiple protection functions.
The NDR-480-24 provides a nominal output voltage of 24V DC, a rated output current of 20A and a rated output power of 480W. The output voltage can be adjusted from 24V to 28V using the front-panel voltage adjustment potentiometer.
The NDR-480-24 supports a single-phase AC input range of 90–264VAC at 47–63Hz. It also supports a DC input range of 127–370VDC.
Yes. The NDR-480-24 features built-in active power factor correction (PFC). Its typical power factor is greater than 0.98 at 115VAC and greater than 0.94 at 230VAC under full load.
The NDR-480-24 achieves a typical efficiency of 92.5%, helping reduce energy consumption and heat generation inside industrial control cabinets.
The NDR-480-24 includes short-circuit, overload, overvoltage and overtemperature protection. Overload protection uses constant-current limiting, with output shutdown after approximately three seconds. Overload and overvoltage shutdown require the power supply to be switched off and powered on again for recovery. Overtemperature protection automatically recovers after the temperature falls.
The specified operating temperature range is −20°C to +70°C. Load derating is required above approximately 50°C ambient temperature, according to the product's derating curve.
The NDR-480-24 measures 85.5 × 125.2 × 128.5 mm (W × H × D) and weighs approximately 1.5 kg. Its slim metal housing is designed to save space in industrial control cabinets.
The NDR-480-24 supports standard TS35/7.5 and TS35/15 DIN rails, making it suitable for installation in electrical panels, control cabinets and industrial automation equipment.
No. The NDR-480-24 uses fanless natural convection cooling. Adequate ventilation clearance must be maintained around the unit to support heat dissipation and reliable operation.
The recommended clearances are 5mm on the left and right, 40mm above and 20mm below the unit. When an adjacent device is a heat source, a clearance of 15mm is recommended. The power supply must be installed vertically, with input terminals at the bottom and output terminals at the top.
Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted between 24V and 28V DC. The output current and power must not exceed the rated limits of 20A and 480W.
The terminal assignments are:
TB1 — Input: Pin 1 = FG, Pin 2 = AC/N or DC−, Pin 3 = AC/L or DC+.
TB2 — Output: Pins 1 and 2 = +V; Pins 3 and 4 = −V.
The TB2 output pin order is reversed compared with NDR-75, NDR-120 and NDR-240 models. Always verify the terminal labels before wiring. The FG terminal must be connected to protective earth (PE).
The NDR-480-24 is certified to UL508, TUV BS EN/EN62368-1 and EAC TP TC 004. It also complies with BS EN/EN61000-6-2 industrial immunity requirements, with additional EMC emission and immunity standards listed in its technical specifications.
The NDR-480-24 is suitable for industrial control systems, factory automation, electrical panels, semiconductor equipment, electromechanical apparatus, machine control, process control, test and measurement equipment, PLC and sensor power circuits, industrial LED lighting, building automation, and security and access control systems.
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
DRM-0840-R Relay Safety Light Curtain Industrial Area Sensor
DRM-1020-R Relay Safety Light Curtain Industrial Area Sensor
DRM-0620-R Relay Safety Light Curtain Industrial Area Sensor
The DAPPRA NDR-480-24 (SKU: OF59) is a 480W single output slim industrial DIN rail power supply designed for higher-power industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 20A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features an 85.5 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting with shutdown), over voltage and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-480-24 delivers a high-efficiency 92.5% power solution for demanding industrial loads.
Engineered for high-power, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-480-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 20A |
| Current Range | 0~20A |
| Rated Power | 480W |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1500ms, 100ms/230VAC · 3000ms, 100ms/115VAC at full load |
| Hold Up Time (Typ.) | 16ms/230VAC · 16ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.98/115VAC · PF >0.94/230VAC at full load |
| Efficiency (Typ.) | 92.5% |
| AC Current (Typ.) | 4.8A/115VAC · 2.4A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <2mA/240VAC |
| Overload | 105~130% rated output power · Constant current limiting · Shut down after ~3s, re-power on to recover |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; auto-recovery after temperature falls |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Refer to Derating Curve) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~50°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class B · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 1041.6K hrs min. Telcordia SR-332 (Bellcore) · 146.8K hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 85.5 × 125.2 × 128.5 mm |
| Weight | 1.5 Kg |
| Packing | 1.5Kg; 8pcs/13Kg/0.9CUFT |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: +V (pins 1,2) / −V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF59.
Slim 85.5 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 85.5 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 128.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 1.5 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-480-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-480-24 operates from −20°C to +70°C, with full-load operation specified up to approximately 50°C ambient. Load derating is required above this temperature according to the derating curve. Do not install in high ambient temperature locations or near fire sources.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-480-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT +V |
| 3, 4 | DC OUTPUT −V |
Note: The NDR-480 TB2 pin order is reversed compared to NDR-75 / 120 / 240. Verify the terminal label before wiring.
The FG pin must be connected to PE (Protective Earth). Both +V pins (1, 2) and both −V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact.
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-480 | 10.35 kgf-cm (9 Lb-in) | 10.35 kgf-cm (9 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-480 | T8A/L250V | 3 | 5 |
Maximum number of NDR-480 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-480-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-480-24 is suitable for higher-power industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-480-24 (SKU: OF59) is a 480W single-output industrial DIN rail power supply designed for industrial control panels, factory automation and electromechanical equipment. It provides 24V DC output at 20A and features built-in active PFC, fanless cooling and multiple protection functions.
The NDR-480-24 provides a nominal output voltage of 24V DC, a rated output current of 20A and a rated output power of 480W. The output voltage can be adjusted from 24V to 28V using the front-panel voltage adjustment potentiometer.
The NDR-480-24 supports a single-phase AC input range of 90–264VAC at 47–63Hz. It also supports a DC input range of 127–370VDC.
Yes. The NDR-480-24 features built-in active power factor correction (PFC). Its typical power factor is greater than 0.98 at 115VAC and greater than 0.94 at 230VAC under full load.
The NDR-480-24 achieves a typical efficiency of 92.5%, helping reduce energy consumption and heat generation inside industrial control cabinets.
The NDR-480-24 includes short-circuit, overload, overvoltage and overtemperature protection. Overload protection uses constant-current limiting, with output shutdown after approximately three seconds. Overload and overvoltage shutdown require the power supply to be switched off and powered on again for recovery. Overtemperature protection automatically recovers after the temperature falls.
The specified operating temperature range is −20°C to +70°C. Load derating is required above approximately 50°C ambient temperature, according to the product's derating curve.
The NDR-480-24 measures 85.5 × 125.2 × 128.5 mm (W × H × D) and weighs approximately 1.5 kg. Its slim metal housing is designed to save space in industrial control cabinets.
The NDR-480-24 supports standard TS35/7.5 and TS35/15 DIN rails, making it suitable for installation in electrical panels, control cabinets and industrial automation equipment.
No. The NDR-480-24 uses fanless natural convection cooling. Adequate ventilation clearance must be maintained around the unit to support heat dissipation and reliable operation.
The recommended clearances are 5mm on the left and right, 40mm above and 20mm below the unit. When an adjacent device is a heat source, a clearance of 15mm is recommended. The power supply must be installed vertically, with input terminals at the bottom and output terminals at the top.
Yes. The front-panel +V ADJ potentiometer allows the output voltage to be adjusted between 24V and 28V DC. The output current and power must not exceed the rated limits of 20A and 480W.
The terminal assignments are:
TB1 — Input: Pin 1 = FG, Pin 2 = AC/N or DC−, Pin 3 = AC/L or DC+.
TB2 — Output: Pins 1 and 2 = +V; Pins 3 and 4 = −V.
The TB2 output pin order is reversed compared with NDR-75, NDR-120 and NDR-240 models. Always verify the terminal labels before wiring. The FG terminal must be connected to protective earth (PE).
The NDR-480-24 is certified to UL508, TUV BS EN/EN62368-1 and EAC TP TC 004. It also complies with BS EN/EN61000-6-2 industrial immunity requirements, with additional EMC emission and immunity standards listed in its technical specifications.
The NDR-480-24 is suitable for industrial control systems, factory automation, electrical panels, semiconductor equipment, electromechanical apparatus, machine control, process control, test and measurement equipment, PLC and sensor power circuits, industrial LED lighting, building automation, and security and access control systems.
Dedi********** (pemilik terverifikasi) –
Model dan spesifikasi sesuai pesanan. Dudukan DIN rail-nya juga sudah ada, jadi lebih praktis untuk pemasangan.
Andi******** (pemilik terverifikasi) –
Barang terlihat bagus, bodinya kokoh dan terminalnya juga rapi. Sesuai dengan yang saya cari.
Sant*** (pemilik terverifikasi) –
Pengiriman cukup cepat, barang sampai dalam kondisi baik. Tidak ada masalah saat paket diterima.
Rudi******** (pemilik terverifikasi) –
Barang sampai dengan aman, packing rapi dan ada plastik pelindungnya juga. Kardus tidak rusak. Terima kasih seller.
supr* (pemilik terverifikasi) –
Barang sudah diterima sesuai pesanan. Kondisi masih bagus dan packing aman. Sejauh ini puas belanja di sini.
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
Dedi********** (pemilik terverifikasi) –
Model dan spesifikasi sesuai pesanan. Dudukan DIN rail-nya juga sudah ada, jadi lebih praktis untuk pemasangan.
Andi******** (pemilik terverifikasi) –
Barang terlihat bagus, bodinya kokoh dan terminalnya juga rapi. Sesuai dengan yang saya cari.
Sant*** (pemilik terverifikasi) –
Pengiriman cukup cepat, barang sampai dalam kondisi baik. Tidak ada masalah saat paket diterima.
Rudi******** (pemilik terverifikasi) –
Barang sampai dengan aman, packing rapi dan ada plastik pelindungnya juga. Kardus tidak rusak. Terima kasih seller.
supr* (pemilik terverifikasi) –
Barang sudah diterima sesuai pesanan. Kondisi masih bagus dan packing aman. Sejauh ini puas belanja di sini.