The DAPPRA HDR-60-24 (SKU: SD95) is a 60W single-output ultra-slim DIN rail power supply in the HDR Series. It provides a stable 24V DC output at 2.5A from a universal 85–264 VAC input, with 90% typical efficiency — the highest in the HDR-60 series — and a ±10% output adjustment range of 21.6–29V.
At 52.5 mm (3SU) wide, the HDR-60-24 provides additional heat dissipation for the 2.5A output compared to the 35 mm HDR-30. Class II double insulation eliminates the need for a protective earth connection, and LPS certification makes it suitable for limited-energy circuits. The 6-pin terminal groups the output pins as −V (1,2) and +V (3,4), with AC/L (5) and AC/N (6) at the end — verify terminal labels before wiring. Protection includes short circuit, overload (105–160% constant current limiting, auto-recovery) and over-voltage (30–36V, shut-off with zener clamping).
Engineered for 24V relay, sensor and control loads requiring up to 2.5A in a compact 3SU footprint.
| DC Voltage | 24V |
| Rated Current | 2.5A |
| Current Range | 0–2.5A |
| Rated Power | 60W |
| Ripple | 150mVp-p |
| Adjustment | 21.6–29V |
| Tolerance | ±1.0% |
| Voltage | 85–264VAC (277VAC op.) · 120–370VDC |
| Efficiency | 90% |
| No-Load | <0.3W |
| Overload | 105–160% · Constant current limiting · Auto-recovery |
| Over Voltage | 30–36V · Shut off, zener clamp |
52.5 mm (3SU) step-shape housing, 90 mm height per DIN EN43880. Tolerance ±0.5 mm.
| Width | 52.5 mm (3SU) |
| Height | 90 mm |
| Depth | 54.5 mm |
| Weight | ~230 g |
| Housing | Plastic, Class II |
| Top/Bottom | 40 / 20 mm |
| Sides | 5 mm |
| DIN Rail | TS35/7.5 or 15 |

Input bottom, output top.
5 mm sides, 40 mm top, 20 mm bottom.
TS35/7.5 or 15.
No grounding required.
−30 to +70°C, full load up to 45°C, derate above 45°C.
Dry, ventilated cabinet.
| Pin | Assignment |
|---|---|
| 1, 2 | −V |
| 3, 4 | +V |
| 5 | AC/L |
| 6 | AC/N |
Output grouped −V first, then +V. AC/L pin 5, AC/N pin 6. No FG/PE.
| +V ADJ | 21.6–29V |
| Power LED | Yes |
| Class II | No PE |
| LPS | Pass |
Contact DAPPRA Automation — or explore the full HDR Series.
The DAPPRA HDR-60-24 (SKU: SD95) is a 60W single-output ultra-slim DIN rail power supply providing 24V DC at 2.5A. It features a 52.5 mm (3SU) plastic step-shape housing, Class II double insulation (no grounding required), LPS certification, and 90% typical efficiency — the highest in the HDR-60 series.
The HDR-60-24 supports a universal AC input range of 85–264VAC (277VAC operational) or 120–370VDC (390VDC operational).
The HDR-60-24 has a 21.6–29V output adjustment range via the front-panel +V ADJ potentiometer (±10% of 24V). This window is sufficient for voltage-drop compensation without exceeding the tolerance of most 24V industrial devices.
The HDR-60-24 triggers over-voltage protection at 30–36V (125–150% of 24V). The protection type is shut-off output voltage with zener clamping, and the unit requires re-powering to recover.
The HDR-60-24 uses 105–160% rated output power protection with constant current limiting. The unit recovers automatically after the fault condition is removed.
The maximum ripple and noise is 150mVp-p, measured at 20MHz bandwidth with a 0.1μF and 47μF parallel capacitor.
The HDR-60-24 measures 52.5 × 90 × 54.5 mm (W × H × D) and weighs approximately 230 g. The 52.5 mm (3SU) width provides additional heat dissipation for the 2.5A output.
TB1 (6 pins): Pins 1, 2 = DC OUTPUT −V; Pins 3, 4 = DC OUTPUT +V; Pin 5 = AC/L; Pin 6 = AC/N. The output pins are grouped as −V first, then +V — this differs from the 4-pin HDR-30 and HDR-15. Verify terminal labels before wiring.
No-load power consumption is below 0.3W, supporting energy-efficient standby operation.
The HDR-60-24 operates from −30°C to +70°C with free air convection cooling. Derating is required above +50°C ambient. Full-load operation is specified up to +45°C.
Yes. Because the HDR-60-24 is Class II double insulated, no protective earth (PE) connection is required. The plastic housing effectively prevents user contact with electrical hazards.
Yes. The HDR-60-24 passes LPS (Limited Power Source) certification, making it suitable for safety-critical circuits that require limited available energy under fault conditions.
The HDR-60-24 is certified to UL508, UL62368-1, EN62368-1 and IEC62368-1. It complies with EN55032/24, EN61000-3-2 Class A and EN61000-3-3, and is backed by a 3-year warranty.
The HDR-60-24 increases the output current to 2.5A (60W vs 36W) and widens the housing from 35 mm (2SU) to 52.5 mm (3SU). It also upgrades the terminal from 4 pins to 6 pins with grouped −V/+V outputs, and raises the typical efficiency from 89% to 90%. Choose the HDR-60-24 when the 24V load exceeds 1.5A but stays within 2.5A.
Yes, if the combined steady-state current stays within 2.5A (60W). Relay pull-in current can be higher than holding current, so add the worst-case relay load to the sensor draw and verify the total before connecting. If the combined load approaches 2.5A, step up to the HDR-100-24 for headroom.
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
DRM-0840-R Relay Safety Light Curtain Industrial Area Sensor
DRM-1020-R Relay Safety Light Curtain Industrial Area Sensor
DRM-0620-R Relay Safety Light Curtain Industrial Area Sensor
The DAPPRA HDR-60-24 (SKU: SD95) is a 60W single-output ultra-slim DIN rail power supply in the HDR Series. It provides a stable 24V DC output at 2.5A from a universal 85–264 VAC input, with 90% typical efficiency — the highest in the HDR-60 series — and a ±10% output adjustment range of 21.6–29V.
At 52.5 mm (3SU) wide, the HDR-60-24 provides additional heat dissipation for the 2.5A output compared to the 35 mm HDR-30. Class II double insulation eliminates the need for a protective earth connection, and LPS certification makes it suitable for limited-energy circuits. The 6-pin terminal groups the output pins as −V (1,2) and +V (3,4), with AC/L (5) and AC/N (6) at the end — verify terminal labels before wiring. Protection includes short circuit, overload (105–160% constant current limiting, auto-recovery) and over-voltage (30–36V, shut-off with zener clamping).
Engineered for 24V relay, sensor and control loads requiring up to 2.5A in a compact 3SU footprint.
| DC Voltage | 24V |
| Rated Current | 2.5A |
| Current Range | 0–2.5A |
| Rated Power | 60W |
| Ripple | 150mVp-p |
| Adjustment | 21.6–29V |
| Tolerance | ±1.0% |
| Voltage | 85–264VAC (277VAC op.) · 120–370VDC |
| Efficiency | 90% |
| No-Load | <0.3W |
| Overload | 105–160% · Constant current limiting · Auto-recovery |
| Over Voltage | 30–36V · Shut off, zener clamp |
52.5 mm (3SU) step-shape housing, 90 mm height per DIN EN43880. Tolerance ±0.5 mm.
| Width | 52.5 mm (3SU) |
| Height | 90 mm |
| Depth | 54.5 mm |
| Weight | ~230 g |
| Housing | Plastic, Class II |
| Top/Bottom | 40 / 20 mm |
| Sides | 5 mm |
| DIN Rail | TS35/7.5 or 15 |

Input bottom, output top.
5 mm sides, 40 mm top, 20 mm bottom.
TS35/7.5 or 15.
No grounding required.
−30 to +70°C, full load up to 45°C, derate above 45°C.
Dry, ventilated cabinet.
| Pin | Assignment |
|---|---|
| 1, 2 | −V |
| 3, 4 | +V |
| 5 | AC/L |
| 6 | AC/N |
Output grouped −V first, then +V. AC/L pin 5, AC/N pin 6. No FG/PE.
| +V ADJ | 21.6–29V |
| Power LED | Yes |
| Class II | No PE |
| LPS | Pass |
Contact DAPPRA Automation — or explore the full HDR Series.
The DAPPRA HDR-60-24 (SKU: SD95) is a 60W single-output ultra-slim DIN rail power supply providing 24V DC at 2.5A. It features a 52.5 mm (3SU) plastic step-shape housing, Class II double insulation (no grounding required), LPS certification, and 90% typical efficiency — the highest in the HDR-60 series.
The HDR-60-24 supports a universal AC input range of 85–264VAC (277VAC operational) or 120–370VDC (390VDC operational).
The HDR-60-24 has a 21.6–29V output adjustment range via the front-panel +V ADJ potentiometer (±10% of 24V). This window is sufficient for voltage-drop compensation without exceeding the tolerance of most 24V industrial devices.
The HDR-60-24 triggers over-voltage protection at 30–36V (125–150% of 24V). The protection type is shut-off output voltage with zener clamping, and the unit requires re-powering to recover.
The HDR-60-24 uses 105–160% rated output power protection with constant current limiting. The unit recovers automatically after the fault condition is removed.
The maximum ripple and noise is 150mVp-p, measured at 20MHz bandwidth with a 0.1μF and 47μF parallel capacitor.
The HDR-60-24 measures 52.5 × 90 × 54.5 mm (W × H × D) and weighs approximately 230 g. The 52.5 mm (3SU) width provides additional heat dissipation for the 2.5A output.
TB1 (6 pins): Pins 1, 2 = DC OUTPUT −V; Pins 3, 4 = DC OUTPUT +V; Pin 5 = AC/L; Pin 6 = AC/N. The output pins are grouped as −V first, then +V — this differs from the 4-pin HDR-30 and HDR-15. Verify terminal labels before wiring.
No-load power consumption is below 0.3W, supporting energy-efficient standby operation.
The HDR-60-24 operates from −30°C to +70°C with free air convection cooling. Derating is required above +50°C ambient. Full-load operation is specified up to +45°C.
Yes. Because the HDR-60-24 is Class II double insulated, no protective earth (PE) connection is required. The plastic housing effectively prevents user contact with electrical hazards.
Yes. The HDR-60-24 passes LPS (Limited Power Source) certification, making it suitable for safety-critical circuits that require limited available energy under fault conditions.
The HDR-60-24 is certified to UL508, UL62368-1, EN62368-1 and IEC62368-1. It complies with EN55032/24, EN61000-3-2 Class A and EN61000-3-3, and is backed by a 3-year warranty.
The HDR-60-24 increases the output current to 2.5A (60W vs 36W) and widens the housing from 35 mm (2SU) to 52.5 mm (3SU). It also upgrades the terminal from 4 pins to 6 pins with grouped −V/+V outputs, and raises the typical efficiency from 89% to 90%. Choose the HDR-60-24 when the 24V load exceeds 1.5A but stays within 2.5A.
Yes, if the combined steady-state current stays within 2.5A (60W). Relay pull-in current can be higher than holding current, so add the worst-case relay load to the sensor draw and verify the total before connecting. If the combined load approaches 2.5A, step up to the HDR-100-24 for headroom.
AL (pemilik terverifikasi) –
kualitas bagus, bintang yg berbicara.
Sri (pemilik terverifikasi) –
Produk Sesuai Deskripsi
hed****** (pemilik terverifikasi) –
barang sesuai pesanan👍
Bim (pemilik terverifikasi) –
trimakasih……………………..👍
M**** (pemilik terverifikasi) –
Produk Sesuai Deskripsi
phry* (pemilik terverifikasi) –
Produk Real Pict Produk Sesuai Deskripsi Packaging Rapi & Aman
Arif (pemilik terverifikasi) –
mantabb
Basr* (pemilik terverifikasi) –
Alex (pemilik terverifikasi) –
duta (pemilik terverifikasi) –
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
AL (pemilik terverifikasi) –
kualitas bagus, bintang yg berbicara.
Sri (pemilik terverifikasi) –
Produk Sesuai Deskripsi
hed****** (pemilik terverifikasi) –
barang sesuai pesanan👍
Bim (pemilik terverifikasi) –
trimakasih……………………..👍
M**** (pemilik terverifikasi) –
Produk Sesuai Deskripsi
phry* (pemilik terverifikasi) –
Produk Real Pict Produk Sesuai Deskripsi Packaging Rapi & Aman
Arif (pemilik terverifikasi) –
mantabb
Basr* (pemilik terverifikasi) –
Alex (pemilik terverifikasi) –
duta (pemilik terverifikasi) –