Belanja minimal Rp 500.000, Gratis Ongkir!

HDR-100-24 100W 24V 3.8A HDR Switch DIN Rail Power Supply

Rp350,000.00

VOUCHER
Diskon 5% min. belanja Rp1JT
Kode: svn56nm9 ·
🔥 21 items sold in last 3 jam
78 orang sedang melihat produk ini sekarang
DAPPRA HDR-100-24 (SKU: SD97) is a 100W single output ultra-slim industrial DIN rail power supply with 24V DC / 4A output. Class II double insulation (no PE required), slim 70 mm plastic housing, <0.3W no-load consumption, TS35 DIN rail mounting — ideal for building automation and industrial control.
24V / 4A
Output
100 W
Rated Power
85–264 VAC
Universal Input
90%
Efficiency
70 mm
Slim Width
Class II
No PE Required
atau

Share:

Overview

HDR-100-24 Overview

The DAPPRA HDR-100-24 (SKU: SD97) is a single-output ultra-slim DIN rail power supply in the HDR Series, available in two versions: the Blank type delivers 24V DC at 3.83A (92W) and passes LPS certification; the N type delivers 24V DC at 4.2A (100.8W) and is Non-LPS. Both share the same 70 mm (4SU) plastic step-shape housing, Class II double insulation, and 90% typical efficiency.

At 70 mm wide, the HDR-100-24 provides additional heat dissipation for the higher 24V current compared to the 52.5 mm HDR-60. The 6-pin terminal places AC/L (1) and AC/N (2) first, followed by −V (3,4) and +V (5,6) — verify terminal labels before wiring, as this differs from the HDR-60. Protection includes short circuit, overload (105–160% constant current limiting, auto-recovery) and over-voltage (28.8–36V, shut-off with zener clamping).

Key Features

HDR-100-24 Key Features

Available in LPS (Blank) and Non-LPS (N) versions for higher-current 24V loads.

  • 92W (Blank) / 100.8W (N) · 24VBlank: 3.83A, Pass LPS, narrower adjustment. N: 4.2A, Non-LPS, wider adjustment (24–28.8V).
  • 70 mm (4SU) Housing70 × 90 × 54.5 mm, DIN EN43880 height. Additional heat dissipation for 4A+ output.
  • Class II Double InsulationNo FG/PE terminal, no grounding required.
  • LPS or Non-LPS ChoiceBlank for LPS compliance; N for maximum 4.2A output.
  • 90% Typical EfficiencyHigh efficiency reduces heat generation.
  • Overload 105–160%Constant current limiting, auto-recovery.
  • 6-Pin TerminalAC/L (1) / AC/N (2) / −V (3,4) / +V (5,6). AC pins first — differs from HDR-60.
Specifications

HDR-100-24 Specifications

Output (Blank / N)

DC Voltage24V
Rated Current3.83A (Blank) / 4.2A (N)
Rated Power92W (Blank) / 100.8W (N)
Ripple150mVp-p
Adjustment (Blank)24–27.6V (LPS)
Adjustment (N)24–28.8V (Non-LPS)
Tolerance±1.0%

Input

Voltage85–264VAC (277VAC op.) · 120–370VDC
Efficiency90%
No-Load<0.3W

Protection

Overload105–160% · Constant current limiting · Auto-recovery
Over Voltage28.8–36V · Shut off, zener clamp
NotesBlank: 3.83A / 92W, LPS. N: 4.2A / 100.8W, Non-LPS. Class II, no PE. Efficiency 90%. AC pins 1–2.
Dimensions

HDR-100-24 Dimensions

70 mm (4SU) step-shape housing, 90 mm height per DIN EN43880. Tolerance ±0.5 mm.

Mechanical
Width70 mm (4SU)
Height90 mm
Depth54.5 mm
Weight~270 g (N type)
HousingPlastic, Class II
Clearances
Top/Bottom40 / 20 mm
Sides5 mm
DIN RailTS35/7.5 or 15
HDR-100-24 Mechanical Dimensions — 70 × 90 × 54.5 mm (4SU)
Installation

HDR-100-24 Installation

01 / 06

Vertical Only

Input bottom, output top.

02 / 06

Clearances

5 mm sides, 40 mm top, 20 mm bottom.

03 / 06

TS35 Rail

TS35/7.5 or 15.

04 / 06

Class II — No PE

No grounding required.

05 / 06

Temperature

−30 to +70°C, derate above 50°C.

06 / 06

Pollution Degree 2

Dry, ventilated cabinet.

Wiring

HDR-100-24 Wiring

TB1 (6 Pins)
PinAssignment
1AC/L
2AC/N
3, 4−V
5, 6+V

AC input pins first (1,2), then −V (3,4) and +V (5,6). No FG/PE.

Front Panel
+V ADJ24–27.6V (Blank) / 24–28.8V (N)
Power LEDYes
Class IINo PE
LPSBlank: Pass / N: Non-LPS
DC OutputBlank: 24–27.6V, 3.83A / 92W, LPS. N: 24–28.8V, 4.2A / 100.8W, Non-LPS. AC pins 1–2.
Safety

HDR-100-24 Safety & Cautions

  • Qualified technician only.
  • Do not connect primary and secondary.
  • Burn hazard.
  • Protect openings.
  • Do not exceed rated output: Blank 3.83A / 92W; N 4.2A / 100.8W.
  • Disconnect before maintenance.
  • Class II — no PE, but final equipment must comply with safety/EMC.
  • Verify AC/L (1) and AC/N (2) — AC pins first on HDR-100.
Applications

HDR-100-24 Industrial Applications

24V Relay Banks
24V Motor Loads
Industrial Control
Building Automation
LPS (Blank Type)
Machine Control
Process Control
Test & Measurement
Next Step

Need the HDR-100-24?

Contact DAPPRA Automation — or explore the full HDR Series.

Support

HDR-100-24 FAQ

What is the DAPPRA HDR-100-24?

The DAPPRA HDR-100-24 (SKU: SD97) is a single-output ultra-slim DIN rail power supply available in two versions: Blank type delivers 24V DC at 3.83A (92W) and passes LPS; N type delivers 24V DC at 4.2A (100.8W) and is Non-LPS. Both share a 70 mm (4SU) housing, Class II insulation, and 90% typical efficiency.

What is the difference between HDR-100-24 Blank type and N type?

Blank: 92W max, 3.83A, Pass LPS, narrower adjustment. N: 100.8W max, 4.2A, Non-LPS, wider adjustment (24–28.8V). Choose Blank for LPS; choose N for maximum 24V output.

What is the input voltage range of the HDR-100-24?

85–264VAC (277VAC operational) or 120–370VDC (390VDC operational).

What is the output voltage adjustment range of the HDR-100-24?

Blank (LPS): 24–27.6V. N (Non-LPS): 24–28.8V. Both via front-panel +V ADJ.

What is the over-voltage protection threshold of the HDR-100-24?

28.8–36V, shut-off with zener clamping; re-power to recover.

What is the overload protection behavior of the HDR-100-24?

105–160% rated output power, constant current limiting, auto-recovery after fault removed.

What is the ripple and noise of the HDR-100-24?

Maximum 150mVp-p at 20MHz bandwidth with 0.1μF & 47μF capacitor.

What are the dimensions and weight of the HDR-100-24?

70 × 90 × 54.5 mm (W × H × D), approx. 270 g (N type). The 70 mm (4SU) width provides heat dissipation for the 4A+ output.

What is the terminal pin assignment of the HDR-100-24?

TB1 (6 pins): Pin 1 = AC/L, Pin 2 = AC/N, Pins 3,4 = −V, Pins 5,6 = +V. AC pins come first — differs from HDR-60 (output first). Verify labels before wiring.

What is the no-load power consumption of the HDR-100-24?

Below 0.3W.

What is the operating temperature range of the HDR-100-24?

−30°C to +70°C with free air convection; derate above +50°C.

Can the HDR-100-24 be used without connecting protective earth?

Yes. Class II double insulated — no PE connection required. Plastic housing prevents user contact with hazards.

Does the HDR-100-24 pass LPS?

Blank type (3.83A / 92W) passes LPS. N type (4.2A / 100.8W) does not. Choose Blank if LPS compliance is required.

What certifications does the HDR-100-24 have?

UL508, UL62368-1, IEC62368-1, EN61558-2-16, EAC TP TC 004. Complies with EN61000-6-2 industrial immunity and EN61000-3-2 Class A.

How does the HDR-100-24 differ from the HDR-60-24?

HDR-100-24 raises current to 3.83A (Blank, 92W) or 4.2A (N, 100.8W) vs 2.5A (60W) on HDR-60-24. Housing widens from 52.5 mm (3SU) to 70 mm (4SU). Terminal moves AC input to pins 1–2 (instead of pins 5–6). Offers LPS (Blank) or Non-LPS (N) choice.

Ulasan

Belum ada ulasan.

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

Overview

HDR-100-24 Overview

The DAPPRA HDR-100-24 (SKU: SD97) is a single-output ultra-slim DIN rail power supply in the HDR Series, available in two versions: the Blank type delivers 24V DC at 3.83A (92W) and passes LPS certification; the N type delivers 24V DC at 4.2A (100.8W) and is Non-LPS. Both share the same 70 mm (4SU) plastic step-shape housing, Class II double insulation, and 90% typical efficiency.

At 70 mm wide, the HDR-100-24 provides additional heat dissipation for the higher 24V current compared to the 52.5 mm HDR-60. The 6-pin terminal places AC/L (1) and AC/N (2) first, followed by −V (3,4) and +V (5,6) — verify terminal labels before wiring, as this differs from the HDR-60. Protection includes short circuit, overload (105–160% constant current limiting, auto-recovery) and over-voltage (28.8–36V, shut-off with zener clamping).

Key Features

HDR-100-24 Key Features

Available in LPS (Blank) and Non-LPS (N) versions for higher-current 24V loads.

  • 92W (Blank) / 100.8W (N) · 24VBlank: 3.83A, Pass LPS, narrower adjustment. N: 4.2A, Non-LPS, wider adjustment (24–28.8V).
  • 70 mm (4SU) Housing70 × 90 × 54.5 mm, DIN EN43880 height. Additional heat dissipation for 4A+ output.
  • Class II Double InsulationNo FG/PE terminal, no grounding required.
  • LPS or Non-LPS ChoiceBlank for LPS compliance; N for maximum 4.2A output.
  • 90% Typical EfficiencyHigh efficiency reduces heat generation.
  • Overload 105–160%Constant current limiting, auto-recovery.
  • 6-Pin TerminalAC/L (1) / AC/N (2) / −V (3,4) / +V (5,6). AC pins first — differs from HDR-60.
Specifications

HDR-100-24 Specifications

Output (Blank / N)

DC Voltage24V
Rated Current3.83A (Blank) / 4.2A (N)
Rated Power92W (Blank) / 100.8W (N)
Ripple150mVp-p
Adjustment (Blank)24–27.6V (LPS)
Adjustment (N)24–28.8V (Non-LPS)
Tolerance±1.0%

Input

Voltage85–264VAC (277VAC op.) · 120–370VDC
Efficiency90%
No-Load<0.3W

Protection

Overload105–160% · Constant current limiting · Auto-recovery
Over Voltage28.8–36V · Shut off, zener clamp
NotesBlank: 3.83A / 92W, LPS. N: 4.2A / 100.8W, Non-LPS. Class II, no PE. Efficiency 90%. AC pins 1–2.
Dimensions

HDR-100-24 Dimensions

70 mm (4SU) step-shape housing, 90 mm height per DIN EN43880. Tolerance ±0.5 mm.

Mechanical
Width70 mm (4SU)
Height90 mm
Depth54.5 mm
Weight~270 g (N type)
HousingPlastic, Class II
Clearances
Top/Bottom40 / 20 mm
Sides5 mm
DIN RailTS35/7.5 or 15
HDR-100-24 Mechanical Dimensions — 70 × 90 × 54.5 mm (4SU)
Installation

HDR-100-24 Installation

01 / 06

Vertical Only

Input bottom, output top.

02 / 06

Clearances

5 mm sides, 40 mm top, 20 mm bottom.

03 / 06

TS35 Rail

TS35/7.5 or 15.

04 / 06

Class II — No PE

No grounding required.

05 / 06

Temperature

−30 to +70°C, derate above 50°C.

06 / 06

Pollution Degree 2

Dry, ventilated cabinet.

Wiring

HDR-100-24 Wiring

TB1 (6 Pins)
PinAssignment
1AC/L
2AC/N
3, 4−V
5, 6+V

AC input pins first (1,2), then −V (3,4) and +V (5,6). No FG/PE.

Front Panel
+V ADJ24–27.6V (Blank) / 24–28.8V (N)
Power LEDYes
Class IINo PE
LPSBlank: Pass / N: Non-LPS
DC OutputBlank: 24–27.6V, 3.83A / 92W, LPS. N: 24–28.8V, 4.2A / 100.8W, Non-LPS. AC pins 1–2.
Safety

HDR-100-24 Safety & Cautions

  • Qualified technician only.
  • Do not connect primary and secondary.
  • Burn hazard.
  • Protect openings.
  • Do not exceed rated output: Blank 3.83A / 92W; N 4.2A / 100.8W.
  • Disconnect before maintenance.
  • Class II — no PE, but final equipment must comply with safety/EMC.
  • Verify AC/L (1) and AC/N (2) — AC pins first on HDR-100.
Applications

HDR-100-24 Industrial Applications

24V Relay Banks
24V Motor Loads
Industrial Control
Building Automation
LPS (Blank Type)
Machine Control
Process Control
Test & Measurement
Next Step

Need the HDR-100-24?

Contact DAPPRA Automation — or explore the full HDR Series.

Support

HDR-100-24 FAQ

What is the DAPPRA HDR-100-24?

The DAPPRA HDR-100-24 (SKU: SD97) is a single-output ultra-slim DIN rail power supply available in two versions: Blank type delivers 24V DC at 3.83A (92W) and passes LPS; N type delivers 24V DC at 4.2A (100.8W) and is Non-LPS. Both share a 70 mm (4SU) housing, Class II insulation, and 90% typical efficiency.

What is the difference between HDR-100-24 Blank type and N type?

Blank: 92W max, 3.83A, Pass LPS, narrower adjustment. N: 100.8W max, 4.2A, Non-LPS, wider adjustment (24–28.8V). Choose Blank for LPS; choose N for maximum 24V output.

What is the input voltage range of the HDR-100-24?

85–264VAC (277VAC operational) or 120–370VDC (390VDC operational).

What is the output voltage adjustment range of the HDR-100-24?

Blank (LPS): 24–27.6V. N (Non-LPS): 24–28.8V. Both via front-panel +V ADJ.

What is the over-voltage protection threshold of the HDR-100-24?

28.8–36V, shut-off with zener clamping; re-power to recover.

What is the overload protection behavior of the HDR-100-24?

105–160% rated output power, constant current limiting, auto-recovery after fault removed.

What is the ripple and noise of the HDR-100-24?

Maximum 150mVp-p at 20MHz bandwidth with 0.1μF & 47μF capacitor.

What are the dimensions and weight of the HDR-100-24?

70 × 90 × 54.5 mm (W × H × D), approx. 270 g (N type). The 70 mm (4SU) width provides heat dissipation for the 4A+ output.

What is the terminal pin assignment of the HDR-100-24?

TB1 (6 pins): Pin 1 = AC/L, Pin 2 = AC/N, Pins 3,4 = −V, Pins 5,6 = +V. AC pins come first — differs from HDR-60 (output first). Verify labels before wiring.

What is the no-load power consumption of the HDR-100-24?

Below 0.3W.

What is the operating temperature range of the HDR-100-24?

−30°C to +70°C with free air convection; derate above +50°C.

Can the HDR-100-24 be used without connecting protective earth?

Yes. Class II double insulated — no PE connection required. Plastic housing prevents user contact with hazards.

Does the HDR-100-24 pass LPS?

Blank type (3.83A / 92W) passes LPS. N type (4.2A / 100.8W) does not. Choose Blank if LPS compliance is required.

What certifications does the HDR-100-24 have?

UL508, UL62368-1, IEC62368-1, EN61558-2-16, EAC TP TC 004. Complies with EN61000-6-2 industrial immunity and EN61000-3-2 Class A.

How does the HDR-100-24 differ from the HDR-60-24?

HDR-100-24 raises current to 3.83A (Blank, 92W) or 4.2A (N, 100.8W) vs 2.5A (60W) on HDR-60-24. Housing widens from 52.5 mm (3SU) to 70 mm (4SU). Terminal moves AC input to pins 1–2 (instead of pins 5–6). Offers LPS (Blank) or Non-LPS (N) choice.