S-50-24 50W 24V DC AC-DC Single Output Enclosed Switching Power Supply

Rp150,000.00

VOUCHER
Diskon 5% min. belanja Rp1JT
Kode: svn56nm9 ·
🔥 7 items sold in last 3 jam
12 orang sedang melihat produk ini sekarang

DAPPRA S-50-24 (SKU: SY06) is a 50.4W single output conventional enclosed switching power supply with 24V DC / 2.1A output. Selectable 85–132 VAC / 170–264 VAC input by switch, 82% typical efficiency, enclosed metal chassis, fanless natural convection cooling, 159 × 97 × 38 mm — ideal for general industrial and commercial applications.

24V / 2.1A
Output

50.4 W
Rated Power

85–264 VAC
Selectable Input

82%
Efficiency

Fanless
Cooling

159 × 97 × 38 mm
Dimensions
atau

Share:

Overview

S-50-24 (SY06) Overview

The DAPPRA S-50-24 (internal code SY06) is a 50.4W single-output enclosed switching power supply delivering 24V DC at 2.1A. It belongs to the S Series conventional enclosed platform, which uses a metal chassis with perforated ventilation and selectable AC input by switch — a cost-effective solution for general industrial and commercial loads that require a single fixed 24V rail.

The S-50-24 uses selectable AC input: 85–132VAC or 170–264VAC via an external selector switch, or 240–370VDC. Efficiency is 82% typical. Free air convection cooling is used without a fan, so the unit operates quietly and requires no fan maintenance. The output voltage can be trimmed from 22.6V to 26.4V via the front-panel +V ADJ potentiometer.

The enclosed metal chassis measures 159 × 97 × 38 mm and weighs approximately 0.51 kg. Protection includes short circuit and overload protection (105–150% fold-back current limiting, auto-recovery). The S-50-24 is suited to 24V relay banks, sensor circuits, small solenoid loads and general 24V industrial control applications where 2.1A is sufficient.

Key Features

S-50-24 Key Features

A 50W 24V enclosed power supply with selectable AC input and fanless cooling.

  • 50.4W Output · 24V / 2.1A24V DC at 2.1A (0–2.1A), 50.4W. +V ADJ range 22.6–26.4V.
  • Selectable AC Input by Switch85–132VAC / 170–264VAC selected by external switch, or 240–370VDC.
  • 82% Typical EfficiencyBalanced efficiency for a conventional 50W enclosed chassis.
  • Free Air Convection CoolingNo fan — quiet operation, no dust intake through a fan, no fan maintenance.
  • Enclosed Metal Chassis with Vents159 × 97 × 38 mm chassis with perforated ventilation for heat dissipation.
  • Overload Protection 105–150%Fold-back current limiting, auto-recovery after fault removal.
  • Short Circuit ProtectionProtected output with auto-recovery.
  • LED Power-On IndicatorFront-panel LED for quick visual status check.
  • -10°C to +60°C Operating RangeWith derating above +50°C.
  • Compact 0.51 kg Enclosed UnitSuitable for standalone mounting inside control cabinets and equipment.
Specifications

S-50-24 (SY06) Specifications

Output

ModelS-50-24 (SY06)
DC Voltage24V
Rated Current2.1A
Current Range0–2.1A
Rated Power50.4W
Voltage Adjustment22.6–26.4V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±0.5%
Ripple & Noise (max.)100mVp-p
Setup / Rise / Hold-up200ms / 100ms / 20ms at full load

Protection

Overload105–150% rated output, fold-back current limiting, auto-recovery
Short CircuitProtected, auto-recovery

Input

Voltage85–132VAC / 170–264VAC (selectable by switch) · 240–370VDC
Frequency47–63Hz
AC Current (typ.)1.3A @ 115VAC · 0.65A @ 230VAC
Inrush Current (max.)18A @ 115VAC · 36A @ 230VAC (cold start)
Leakage Current<1mA @ 240VAC
Efficiency (typ.)82%

Switching Frequency

Fixed Switching Frequency27 kHz

Environment

Working Temperature-10 ~ +60°C (derating above +50°C)
Storage Temperature-20 ~ +85°C
Working Humidity20–90% RH non-condensing
Temperature Coefficient0.03%/°C (0 ~ 50°C)
Vibration10–500Hz, 2G, 10min/cycle, 60min each axis

Safety & EMC

Safety StandardsDesign refer to UL1012
Withstand VoltageI/P–O/P: 1.5kVAC · I/P–FG: 1.5kVAC · O/P–FG: 0.5kVAC
Isolation Resistance100MΩ / 500VDC
EMC EmissionDesign refer to FCC Part15 J Conduction Class B

Mechanical

Dimensions (L×W×H)159 × 97 × 38 mm
WeightApprox. 0.51 kg
HousingEnclosed metal chassis with vents
CoolingFree air convection (fanless)
Warranty1 Year

Terminal Assignment

PinFunction
1AC/L
2AC/N
3FG (must connect to PE)
4DC OUTPUT −V
5DC OUTPUT +V
Notes 24V / 2.1A / 50.4W. Selectable AC input by switch — verify the switch position before applying power. 5-pin terminal: AC/L, AC/N, FG, −V, +V. Fanless, 159 × 97 × 38 mm. Derating above +50°C. 1-year warranty.
Dimensions

S-50-24 Dimensions

Enclosed metal chassis with perforated ventilation. All dimensions in mm, tolerance ±1 mm.

Mechanical
Length (L)159 mm
Width (W)97 mm
Height (H)38 mm
WeightApprox. 0.51 kg
HousingEnclosed metal chassis with vents
Clearances & Mounting
Top / Bottom40 mm / 20 mm
Left / Right5 mm / 5 mm
Adjacent Heat SourceKeep at least 100 mm clearance
MountingChassis base mounting holes
CoolingFree air convection (no fan)
Installation

S-50-24 Installation

The S-50-24 uses an enclosed chassis design for standalone mounting inside industrial equipment.

01 / 06

Chassis Mounting

Mount the unit on a flat metal surface using the chassis base mounting holes. Secure the unit to prevent vibration and movement.

02 / 06

Ventilation Clearance

Allow at least 5 mm left/right, 40 mm above and 20 mm below. Do not block the perforated ventilation openings.

03 / 06

Input Voltage Selector

Set the 115V/230V selector switch to match the actual mains voltage before applying power. Wrong setting can damage the unit.

04 / 06

FG to PE Required

The FG terminal (Pin 3) must be connected to PE (Protective Earth) for safety and EMC performance.

05 / 06

Temperature & Derating

-10 to +60°C. Derate above +50°C according to the output load derating curve.

06 / 06

Indoor Use Only

Install in a dry, well-ventilated location. Do not install near water or in high-moisture environments.

Wiring

S-50-24 Wiring & Terminal

5-pin screw terminal block. Verify pin numbering before wiring.

Terminal Block — 5 Pins
PinFunction
1AC/L
2AC/N
3FG (must connect to PE)
4DC OUTPUT −V
5DC OUTPUT +V
Wiring Specification
Screw Torque5–6 kgf-cm (4.4–5.2 Lb-in)
Wire TypeStranded copper only, 80°C minimum
Recommended Wire (2.1A)18 AWG (0.75 mm²) or larger
Wire Strapping Length5 mm (0.197")
Screwdriver3 mm slotted
FG ConnectionMust be connected to PE

Verify the input voltage selector switch position before applying power. The FG pin (Pin 3) must be connected to PE. Do not connect the primary and secondary sides together.

Output Voltage Adjustment The S-50-24 includes a front-panel +V ADJ potentiometer with a 22.6–26.4V range and a power-on LED indicator. Output current and wattage must not exceed the rated 2.1A / 50.4W.
Safety

S-50-24 Safety & Cautions

  • Qualified technician only. Do not remove the case yourself.
  • Do not connect primary and secondary sides together — electric shock / arc hazard.
  • Burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Protect ventilation openings from foreign objects and dripping liquids.
  • FG (Pin 3) must be connected to PE (Protective Earth).
  • Do not exceed 2.1A / 50.4W rated output.
  • Disconnect the system from supply voltage before installation, maintenance or modification.
  • Verify the input voltage selector switch position before applying power.
  • Component for final equipment; final EMC must be re-confirmed.
Applications

S-50-24 Industrial Applications

24V Relay Banks
Sensor Circuits
Industrial Control Systems
Small Solenoid Loads
Electronic Instruments
LED Lighting
Security Systems
General 24V Equipment
Next Step

Need the S-50-24 (SY06)?

Contact DAPPRA Automation — or explore the full S Series.

Support

S-50-24 FAQ

What is the DAPPRA S-50-24 (SY06)?

The S-50-24 (internal code SY06) is a 50.4W single-output enclosed switching power supply delivering 24V DC at 2.1A. It belongs to the DAPPRA S Series conventional enclosed platform, uses selectable AC input 85–132VAC / 170–264VAC by switch (or 240–370VDC), achieves 82% typical efficiency, and uses free air convection cooling without a fan.

What is the input voltage range of the S-50-24?

The S-50-24 uses selectable AC input: 85–132VAC or 170–264VAC selected by an external switch, or 240–370VDC. Input frequency is 47–63Hz.

What output voltage and current does the S-50-24 provide?

The S-50-24 provides 24V DC at 2.1A for a rated output of 50.4W. The output voltage adjustment range is 22.6–26.4V via the front-panel +V ADJ potentiometer.

Does the S-50-24 require a cooling fan?

No. The S-50-24 uses free air convection cooling without a fan. It is designed for quiet, low-maintenance installations.

What is the efficiency of the S-50-24?

The S-50-24 achieves 82% typical efficiency at 230VAC input and rated load.

What are the dimensions of the S-50-24?

The S-50-24 measures 159 × 97 × 38 mm (L × W × H) in an enclosed metal chassis with ventilation vents. Weight is approximately 0.51 kg.

What protections does the S-50-24 include?

The S-50-24 includes short circuit protection and overload protection (105–150% rated output power, fold-back current limiting, auto-recovery).

What is the terminal pin assignment of the S-50-24?

The S-50-24 uses a 5-pin terminal block: Pin 1 = AC/L, Pin 2 = AC/N, Pin 3 = FG (Frame Ground), Pin 4 = DC OUTPUT −V, Pin 5 = DC OUTPUT +V. FG must be connected to PE.

What is the operating temperature range of the S-50-24?

The S-50-24 operates from -10°C to +60°C with derating required above +50°C.

What certifications does the S-50-24 have?

The S-50-24 is designed referring to UL1012 and FCC Part15 J Conduction Class B. Confirm the specific marking on the DAPPRA-labeled unit.

What is the warranty period for the S-50-24?

The S-50-24 comes with a 1-year warranty.

Ulasan

Belum ada ulasan.

Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.

Overview

S-50-24 (SY06) Overview

The DAPPRA S-50-24 (internal code SY06) is a 50.4W single-output enclosed switching power supply delivering 24V DC at 2.1A. It belongs to the S Series conventional enclosed platform, which uses a metal chassis with perforated ventilation and selectable AC input by switch — a cost-effective solution for general industrial and commercial loads that require a single fixed 24V rail.

The S-50-24 uses selectable AC input: 85–132VAC or 170–264VAC via an external selector switch, or 240–370VDC. Efficiency is 82% typical. Free air convection cooling is used without a fan, so the unit operates quietly and requires no fan maintenance. The output voltage can be trimmed from 22.6V to 26.4V via the front-panel +V ADJ potentiometer.

The enclosed metal chassis measures 159 × 97 × 38 mm and weighs approximately 0.51 kg. Protection includes short circuit and overload protection (105–150% fold-back current limiting, auto-recovery). The S-50-24 is suited to 24V relay banks, sensor circuits, small solenoid loads and general 24V industrial control applications where 2.1A is sufficient.

Key Features

S-50-24 Key Features

A 50W 24V enclosed power supply with selectable AC input and fanless cooling.

  • 50.4W Output · 24V / 2.1A24V DC at 2.1A (0–2.1A), 50.4W. +V ADJ range 22.6–26.4V.
  • Selectable AC Input by Switch85–132VAC / 170–264VAC selected by external switch, or 240–370VDC.
  • 82% Typical EfficiencyBalanced efficiency for a conventional 50W enclosed chassis.
  • Free Air Convection CoolingNo fan — quiet operation, no dust intake through a fan, no fan maintenance.
  • Enclosed Metal Chassis with Vents159 × 97 × 38 mm chassis with perforated ventilation for heat dissipation.
  • Overload Protection 105–150%Fold-back current limiting, auto-recovery after fault removal.
  • Short Circuit ProtectionProtected output with auto-recovery.
  • LED Power-On IndicatorFront-panel LED for quick visual status check.
  • -10°C to +60°C Operating RangeWith derating above +50°C.
  • Compact 0.51 kg Enclosed UnitSuitable for standalone mounting inside control cabinets and equipment.
Specifications

S-50-24 (SY06) Specifications

Output

ModelS-50-24 (SY06)
DC Voltage24V
Rated Current2.1A
Current Range0–2.1A
Rated Power50.4W
Voltage Adjustment22.6–26.4V
Voltage Tolerance±1.0%
Line Regulation±0.5%
Load Regulation±0.5%
Ripple & Noise (max.)100mVp-p
Setup / Rise / Hold-up200ms / 100ms / 20ms at full load

Protection

Overload105–150% rated output, fold-back current limiting, auto-recovery
Short CircuitProtected, auto-recovery

Input

Voltage85–132VAC / 170–264VAC (selectable by switch) · 240–370VDC
Frequency47–63Hz
AC Current (typ.)1.3A @ 115VAC · 0.65A @ 230VAC
Inrush Current (max.)18A @ 115VAC · 36A @ 230VAC (cold start)
Leakage Current<1mA @ 240VAC
Efficiency (typ.)82%

Switching Frequency

Fixed Switching Frequency27 kHz

Environment

Working Temperature-10 ~ +60°C (derating above +50°C)
Storage Temperature-20 ~ +85°C
Working Humidity20–90% RH non-condensing
Temperature Coefficient0.03%/°C (0 ~ 50°C)
Vibration10–500Hz, 2G, 10min/cycle, 60min each axis

Safety & EMC

Safety StandardsDesign refer to UL1012
Withstand VoltageI/P–O/P: 1.5kVAC · I/P–FG: 1.5kVAC · O/P–FG: 0.5kVAC
Isolation Resistance100MΩ / 500VDC
EMC EmissionDesign refer to FCC Part15 J Conduction Class B

Mechanical

Dimensions (L×W×H)159 × 97 × 38 mm
WeightApprox. 0.51 kg
HousingEnclosed metal chassis with vents
CoolingFree air convection (fanless)
Warranty1 Year

Terminal Assignment

PinFunction
1AC/L
2AC/N
3FG (must connect to PE)
4DC OUTPUT −V
5DC OUTPUT +V
Notes 24V / 2.1A / 50.4W. Selectable AC input by switch — verify the switch position before applying power. 5-pin terminal: AC/L, AC/N, FG, −V, +V. Fanless, 159 × 97 × 38 mm. Derating above +50°C. 1-year warranty.
Dimensions

S-50-24 Dimensions

Enclosed metal chassis with perforated ventilation. All dimensions in mm, tolerance ±1 mm.

Mechanical
Length (L)159 mm
Width (W)97 mm
Height (H)38 mm
WeightApprox. 0.51 kg
HousingEnclosed metal chassis with vents
Clearances & Mounting
Top / Bottom40 mm / 20 mm
Left / Right5 mm / 5 mm
Adjacent Heat SourceKeep at least 100 mm clearance
MountingChassis base mounting holes
CoolingFree air convection (no fan)
Installation

S-50-24 Installation

The S-50-24 uses an enclosed chassis design for standalone mounting inside industrial equipment.

01 / 06

Chassis Mounting

Mount the unit on a flat metal surface using the chassis base mounting holes. Secure the unit to prevent vibration and movement.

02 / 06

Ventilation Clearance

Allow at least 5 mm left/right, 40 mm above and 20 mm below. Do not block the perforated ventilation openings.

03 / 06

Input Voltage Selector

Set the 115V/230V selector switch to match the actual mains voltage before applying power. Wrong setting can damage the unit.

04 / 06

FG to PE Required

The FG terminal (Pin 3) must be connected to PE (Protective Earth) for safety and EMC performance.

05 / 06

Temperature & Derating

-10 to +60°C. Derate above +50°C according to the output load derating curve.

06 / 06

Indoor Use Only

Install in a dry, well-ventilated location. Do not install near water or in high-moisture environments.

Wiring

S-50-24 Wiring & Terminal

5-pin screw terminal block. Verify pin numbering before wiring.

Terminal Block — 5 Pins
PinFunction
1AC/L
2AC/N
3FG (must connect to PE)
4DC OUTPUT −V
5DC OUTPUT +V
Wiring Specification
Screw Torque5–6 kgf-cm (4.4–5.2 Lb-in)
Wire TypeStranded copper only, 80°C minimum
Recommended Wire (2.1A)18 AWG (0.75 mm²) or larger
Wire Strapping Length5 mm (0.197")
Screwdriver3 mm slotted
FG ConnectionMust be connected to PE

Verify the input voltage selector switch position before applying power. The FG pin (Pin 3) must be connected to PE. Do not connect the primary and secondary sides together.

Output Voltage Adjustment The S-50-24 includes a front-panel +V ADJ potentiometer with a 22.6–26.4V range and a power-on LED indicator. Output current and wattage must not exceed the rated 2.1A / 50.4W.
Safety

S-50-24 Safety & Cautions

  • Qualified technician only. Do not remove the case yourself.
  • Do not connect primary and secondary sides together — electric shock / arc hazard.
  • Burn hazard. Do not touch the unit in operation and shortly after disconnection.
  • Protect ventilation openings from foreign objects and dripping liquids.
  • FG (Pin 3) must be connected to PE (Protective Earth).
  • Do not exceed 2.1A / 50.4W rated output.
  • Disconnect the system from supply voltage before installation, maintenance or modification.
  • Verify the input voltage selector switch position before applying power.
  • Component for final equipment; final EMC must be re-confirmed.
Applications

S-50-24 Industrial Applications

24V Relay Banks
Sensor Circuits
Industrial Control Systems
Small Solenoid Loads
Electronic Instruments
LED Lighting
Security Systems
General 24V Equipment
Next Step

Need the S-50-24 (SY06)?

Contact DAPPRA Automation — or explore the full S Series.

Support

S-50-24 FAQ

What is the DAPPRA S-50-24 (SY06)?

The S-50-24 (internal code SY06) is a 50.4W single-output enclosed switching power supply delivering 24V DC at 2.1A. It belongs to the DAPPRA S Series conventional enclosed platform, uses selectable AC input 85–132VAC / 170–264VAC by switch (or 240–370VDC), achieves 82% typical efficiency, and uses free air convection cooling without a fan.

What is the input voltage range of the S-50-24?

The S-50-24 uses selectable AC input: 85–132VAC or 170–264VAC selected by an external switch, or 240–370VDC. Input frequency is 47–63Hz.

What output voltage and current does the S-50-24 provide?

The S-50-24 provides 24V DC at 2.1A for a rated output of 50.4W. The output voltage adjustment range is 22.6–26.4V via the front-panel +V ADJ potentiometer.

Does the S-50-24 require a cooling fan?

No. The S-50-24 uses free air convection cooling without a fan. It is designed for quiet, low-maintenance installations.

What is the efficiency of the S-50-24?

The S-50-24 achieves 82% typical efficiency at 230VAC input and rated load.

What are the dimensions of the S-50-24?

The S-50-24 measures 159 × 97 × 38 mm (L × W × H) in an enclosed metal chassis with ventilation vents. Weight is approximately 0.51 kg.

What protections does the S-50-24 include?

The S-50-24 includes short circuit protection and overload protection (105–150% rated output power, fold-back current limiting, auto-recovery).

What is the terminal pin assignment of the S-50-24?

The S-50-24 uses a 5-pin terminal block: Pin 1 = AC/L, Pin 2 = AC/N, Pin 3 = FG (Frame Ground), Pin 4 = DC OUTPUT −V, Pin 5 = DC OUTPUT +V. FG must be connected to PE.

What is the operating temperature range of the S-50-24?

The S-50-24 operates from -10°C to +60°C with derating required above +50°C.

What certifications does the S-50-24 have?

The S-50-24 is designed referring to UL1012 and FCC Part15 J Conduction Class B. Confirm the specific marking on the DAPPRA-labeled unit.

What is the warranty period for the S-50-24?

The S-50-24 comes with a 1-year warranty.