Tidak ada produk dalam daftar keinginan.
Tidak ada produk di keranjang.
Rp520,000.00
DAPPRA NDR-240-24 (SKU: OF58) is a 240W single output slim industrial DIN rail power supply with 24V DC / 10A output and universal 90–264 VAC input. Built-in active PFC, 88.5% typical efficiency, slim 63 mm metal housing, fanless natural convection cooling, complete protection functions, UL508 approved, TS35 DIN rail mounting, 3-year warranty — ideal for medium-power industrial control, factory automation and electrical panels.
The DAPPRA NDR-240-24 (SKU: OF58) is a 240W single output slim industrial DIN rail power supply designed for medium-power industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 10A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features a 63 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting, auto-recovery), over voltage (29–33V) and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-240-24 delivers a reliable 88.5% efficiency 24V power solution for demanding industrial loads.
Engineered for medium-power, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-240-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 10A |
| Current Range | 0~10A |
| Rated Power | 240W |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1500ms, 100ms/230VAC · 3000ms, 100ms/115VAC at full load |
| Hold Up Time (Typ.) | 28ms/230VAC · 22ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.98/115VAC · PF >0.95/230VAC at full load |
| Efficiency (Typ.) | 88.5% |
| AC Current (Typ.) | 2.5A/115VAC · 1.3A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <1mA/240VAC |
| Overload | 105~130% rated output power · Constant current limiting · Auto-recovery after fault removed |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; auto-recovery after temperature falls |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Refer to Derating Curve; full load up to 50°C) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~50°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004; meets BS EN/EN60204-1 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class B · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 1645.2K hrs min. Telcordia SR-332 (Bellcore) · 230.2K hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 63 × 125.2 × 113.5 mm |
| Weight | 1.0 Kg |
| Packing | 1.0Kg; 12pcs/13Kg/1.1CUFT |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: −V (pins 1,2) / +V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF58.
Slim 63 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 63 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 113.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 1.0 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-240-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-240-24 operates from −20°C to +70°C, with full-load operation specified up to 50°C ambient. Refer to the derating curve for operation above 50°C.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-240-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT −V |
| 3, 4 | DC OUTPUT +V |
The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-240 | 7.5 kgf-cm (6.5 Lb-in) | 7.5 kgf-cm (6.5 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-240 | T5A/L250V | 4 | 10 |
Maximum number of NDR-240 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-240-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-240-24 is suitable for medium-power industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-240-24 (SKU: OF58) is a 240W industrial DIN rail power supply that delivers 24V DC at a rated current of 10A. It is designed for compatible industrial control panels and automation equipment.
The NDR-240-24 provides 24V DC, up to 10A, with a rated output power of 240W. The combined load should remain within these ratings under the actual operating conditions.
Yes, provided the connected devices all accept 24V DC and their combined steady-state and startup current stays within the power supply's capacity. Check each device's electrical specifications and account for any inductive loads.
The NDR-240-24 has an adjustable output range of 24–28V DC using the front-panel +V ADJ control. Before increasing the voltage, confirm that every connected device can tolerate the selected voltage.
The NDR-240-24 supports a universal AC input range of 90–264VAC (47–63Hz) and a DC input range of 127–370VDC. DC input operation is possible by connecting AC/L(+) and AC/N(−).
Yes. The NDR-240-24 includes built-in active power factor correction (PFC), with a typical power factor greater than 0.98 at 115VAC and greater than 0.95 at 230VAC under full load.
The front panel has a DC OK indicator. Check the indicator together with a voltage measurement at the output terminals and, if necessary, at the connected load.
It depends on the total load. Add the rated power consumption of the PLC, HMI, sensors, relays, valves and other connected devices, then allow additional capacity for startup current and future expansion.
Do not assume it can drive a motor directly. Check the motor's voltage, current, startup demand and drive requirements. A motor requiring a dedicated driver or controller should be connected through compatible equipment.
Use appropriately rated conductors and terminals, observe positive and negative polarity, and consider the current carried by each branch. Separate branch protection may be needed depending on the equipment and applicable electrical standards.
Long cables can cause voltage drop, especially when loads draw substantial current. Select the wire size based on current, cable length and acceptable voltage drop, and measure voltage at the load during operation.
Yes. The NDR-240-24 is designed for TS35/7.5 and TS35/15 DIN rail mounting in industrial control cabinets. Ensure the unit is securely installed with adequate ventilation.
Check the cabinet temperature, load level, ventilation openings and installation clearance. The NDR-240-24 uses natural-convection cooling with a 50°C ambient full-load limit. Consult the derating curve for operation above 50°C.
Measure the output voltage under load and inspect terminal tightness, cable voltage drop, total current demand and input voltage. Also check whether startup current or a faulty downstream device is causing the supply to enter a protection state.
Provide the required quantity, input supply voltage, total 24V load, installation conditions and any documentation or certification requirements. This helps confirm suitability for the intended control system.
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
DRM-0840-R Relay Safety Light Curtain Industrial Area Sensor
DRM-1020-R Relay Safety Light Curtain Industrial Area Sensor
DRM-0620-R Relay Safety Light Curtain Industrial Area Sensor
The DAPPRA NDR-240-24 (SKU: OF58) is a 240W single output slim industrial DIN rail power supply designed for medium-power industrial control, factory automation and electromechanical applications. It provides a stable 24V DC output at 10A rated current from a universal 90–264 VAC input or 127–370 VDC input, and includes built-in active PFC for improved power quality.
The unit features a 63 mm wide metal housing that enhances power dissipation, fanless natural convection cooling, and complete protection functions including short circuit, overload (constant current limiting, auto-recovery), over voltage (29–33V) and over temperature protection. Designed for TS35/7.5 or TS35/15 DIN rail mounting and certified to UL508, the NDR-240-24 delivers a reliable 88.5% efficiency 24V power solution for demanding industrial loads.
Engineered for medium-power, space-saving 24V industrial power supply applications.
Complete technical specifications for the NDR-240-24 industrial DIN rail power supply.
| DC Output Voltage | 24V |
| Rated Current | 10A |
| Current Range | 0~10A |
| Rated Power | 240W |
| Ripple & Noise (max.) | 150mVp-p |
| Voltage Adjustment Range | 24~28V |
| Voltage Tolerance | ±1.0% |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup, Rise Time | 1500ms, 100ms/230VAC · 3000ms, 100ms/115VAC at full load |
| Hold Up Time (Typ.) | 28ms/230VAC · 22ms/115VAC at full load |
| Voltage Range | 90~264VAC · 127~370VDC |
| Frequency Range | 47~63Hz |
| Power Factor (Typ.) | PF >0.98/115VAC · PF >0.95/230VAC at full load |
| Efficiency (Typ.) | 88.5% |
| AC Current (Typ.) | 2.5A/115VAC · 1.3A/230VAC |
| Inrush Current (Typ.) | 20A/115VAC · 35A/230VAC |
| Leakage Current | <1mA/240VAC |
| Overload | 105~130% rated output power · Constant current limiting · Auto-recovery after fault removed |
| Over Voltage | 29~33V · Shut down output, re-power on to recover |
| Over Temperature | Shut down output; auto-recovery after temperature falls |
| Short Circuit | Protected |
| Working Temperature | −20 ~ +70°C (Refer to Derating Curve; full load up to 50°C) |
| Working Humidity | 20~95% RH non-condensing |
| Storage Temp., Humidity | −40 ~ +85°C, 10~95% RH |
| Temp. Coefficient | ±0.03%/°C (0~50°C) |
| Vibration | 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety Standards | UL508, TUV BS EN/EN62368-1, EAC TP TC 004; meets BS EN/EN60204-1 |
| Withstand Voltage | I/P-O/P: 3KVAC · I/P-FG: 2KVAC · O/P-FG: 0.5KVAC |
| Isolation Resistance | >100M Ohms / 500VDC / 25°C / 70% RH |
| EMC Emission | BS EN/EN55032 (CISPR32) Class B · BS EN/EN61000-3-2,-3 |
| EMC Immunity | BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 · BS EN/EN61000-6-2 (BS EN/EN50082-2) heavy industry level |
| MTBF | 1645.2K hrs min. Telcordia SR-332 (Bellcore) · 230.2K hrs min. MIL-HDBK-217F (25°C) |
| Dimensions (W×H×D) | 63 × 125.2 × 113.5 mm |
| Weight | 1.0 Kg |
| Packing | 1.0Kg; 12pcs/13Kg/1.1CUFT |
| Warranty | 3 Years |
| +V ADJ | Output voltage adjustment potentiometer (24~28V) |
| DC OK | DC output OK indicator LED |
| Terminal TB1 | Input: FG / AC-N-DC− / AC-L-DC+ |
| Terminal TB2 | Output: −V (pins 1,2) / +V (pins 3,4) |
The model number identifies the NDR Series, output wattage and output voltage. DAPPRA SKU for this model: OF58.
Slim 63 mm metal housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 63 mm |
| Height (H) | 125.2 mm |
| Depth (D) | 113.5 mm |
| DIN Rail Slot to Top (S) | 35 mm |
| Weight | 1.0 Kg |
| Front Panel | +V ADJ / DC OK |
| Top Clearance | 40 mm |
| Bottom Clearance | 20 mm |
| Left / Right Clearance | 5 mm |
| Adjacent Heat Source | 15 mm recommended |
| DIN Rail | TS35/7.5 or TS35/15 |
| Mounting Orientation | Vertical only (input bottom, output top) |
The NDR-240-24 supports TS35 DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 15 mm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
The NDR-240-24 operates from −20°C to +70°C, with full-load operation specified up to 50°C ambient. Refer to the derating curve for operation above 50°C.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The NDR-240-24 uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N or DC− |
| 3 | AC/L or DC+ |
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT −V |
| 3, 4 | DC OUTPUT +V |
The FG pin must be connected to PE (Protective Earth). Both −V pins (1, 2) and both +V pins (3, 4) should be connected to their respective output wires to prevent excessive current stress on a single contact. DC input operation is possible by connecting AC/L(+), AC/N(−).
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 7 A | 0.8 mm² |
| 16 | 10 A | 1.3 mm² |
| 14 | 15 A | 2.1 mm² |
| 12 | 20 A | 3.3 mm² |
Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model | I/P | O/P |
|---|---|---|
| NDR-240 | 7.5 kgf-cm (6.5 Lb-in) | 7.5 kgf-cm (6.5 Lb-in) |
Recommended wire strapping length: 5 mm (0.197"). Recommended screwdriver: 3 mm, slotted type.
| Model | Fuse | C16 | D16 |
|---|---|---|---|
| NDR-240 | T5A/L250V | 4 | 10 |
Maximum number of NDR-240 PSUs that can be connected to a circuit breaker at 230V. For continued protection against risk of fire, replace only with the same type and rating of fuse.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the NDR-240-24 power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The NDR-240-24 is suitable for medium-power industrial control systems, factory automation equipment, electromechanical apparatus, electrical panels and semiconductor manufacturing equipment.
Contact DAPPRA Automation for product specifications, installation support, technical documentation and purchasing assistance — or explore the full NDR Series and industrial power supply range.
The DAPPRA NDR-240-24 (SKU: OF58) is a 240W industrial DIN rail power supply that delivers 24V DC at a rated current of 10A. It is designed for compatible industrial control panels and automation equipment.
The NDR-240-24 provides 24V DC, up to 10A, with a rated output power of 240W. The combined load should remain within these ratings under the actual operating conditions.
Yes, provided the connected devices all accept 24V DC and their combined steady-state and startup current stays within the power supply's capacity. Check each device's electrical specifications and account for any inductive loads.
The NDR-240-24 has an adjustable output range of 24–28V DC using the front-panel +V ADJ control. Before increasing the voltage, confirm that every connected device can tolerate the selected voltage.
The NDR-240-24 supports a universal AC input range of 90–264VAC (47–63Hz) and a DC input range of 127–370VDC. DC input operation is possible by connecting AC/L(+) and AC/N(−).
Yes. The NDR-240-24 includes built-in active power factor correction (PFC), with a typical power factor greater than 0.98 at 115VAC and greater than 0.95 at 230VAC under full load.
The front panel has a DC OK indicator. Check the indicator together with a voltage measurement at the output terminals and, if necessary, at the connected load.
It depends on the total load. Add the rated power consumption of the PLC, HMI, sensors, relays, valves and other connected devices, then allow additional capacity for startup current and future expansion.
Do not assume it can drive a motor directly. Check the motor's voltage, current, startup demand and drive requirements. A motor requiring a dedicated driver or controller should be connected through compatible equipment.
Use appropriately rated conductors and terminals, observe positive and negative polarity, and consider the current carried by each branch. Separate branch protection may be needed depending on the equipment and applicable electrical standards.
Long cables can cause voltage drop, especially when loads draw substantial current. Select the wire size based on current, cable length and acceptable voltage drop, and measure voltage at the load during operation.
Yes. The NDR-240-24 is designed for TS35/7.5 and TS35/15 DIN rail mounting in industrial control cabinets. Ensure the unit is securely installed with adequate ventilation.
Check the cabinet temperature, load level, ventilation openings and installation clearance. The NDR-240-24 uses natural-convection cooling with a 50°C ambient full-load limit. Consult the derating curve for operation above 50°C.
Measure the output voltage under load and inspect terminal tightness, cable voltage drop, total current demand and input voltage. Also check whether startup current or a faulty downstream device is causing the supply to enter a protection state.
Provide the required quantity, input supply voltage, total 24V load, installation conditions and any documentation or certification requirements. This helps confirm suitability for the intended control system.
Arif (pemilik terverifikasi) –
nurk***** (pemilik terverifikasi) –
Hanya pelanggan yang telah membeli produk ini dapat memberikan ulasan.
Arif (pemilik terverifikasi) –
nurk***** (pemilik terverifikasi) –