The DAPPRA MDR Series is an ultra-slim plastic-housing single-output DIN rail power supply series designed for space-constrained industrial control and automation applications.
Covering 10W to 96W with 5V to 48V output, the MDR Series combines a narrow profile from just 22.5 mm, universal 85–264 VAC input and fanless natural convection cooling. Models from 40W and above include a DC OK relay contact and are certified for Class I, Div 2 hazardous locations.
The DAPPRA MDR Series is an ultra-slim plastic-housing DIN rail power supply series designed for space-constrained industrial control and automation applications. It covers five power ratings — 10W, 20W, 40W, 60W and 96W — with single-output configurations of 5V, 12V, 15V, 24V and 48V DC.
The series features a universal AC input range of 85–264 VAC, fanless natural convection cooling and complete protection functions including short circuit, overload and over voltage protection. The MDR-40, MDR-60 and MDR-100 models include a DC OK relay contact and are certified for Class I, Div 2 Hazardous Locations T4. All models are designed for standard TS35/7.5 or TS35/15 DIN rail mounting.
Engineered for ultra-slim, space-saving industrial power supply applications.
Select the appropriate MDR model according to the required output power, output voltage and DC OK function.
The MDR Series is available in five power ratings — 10W, 20W, 40W, 60W and 96W. The MDR-10 and MDR-20 offer 5V, 12V, 15V and 24V outputs; the MDR-40 and MDR-60 offer 5V, 12V, 24V and 48V; the MDR-100 offers 12V, 24V and 48V. Models from 40W and above include a DC OK relay contact.
| Model | Output Voltage | Output Current | Rated Power | Efficiency | DC OK | Width |
|---|---|---|---|---|---|---|
| MDR-10-5 | 5 VDC | 2 A | 10 W | 77% | Active signal | 22.5 mm |
| MDR-10-12 | 12 VDC | 0.84 A | 10 W | 81% | Active signal | 22.5 mm |
| MDR-10-15 | 15 VDC | 0.67 A | 10 W | 81% | Active signal | 22.5 mm |
| MDR-10-24 | 24 VDC | 0.42 A | 10 W | 81% | Active signal | 22.5 mm |
| MDR-20-5 | 5 VDC | 3 A | 15 W | 76% | Active signal | 22.5 mm |
| MDR-20-12 | 12 VDC | 1.67 A | 20 W | 80% | Active signal | 22.5 mm |
| MDR-20-15 | 15 VDC | 1.34 A | 20 W | 81% | Active signal | 22.5 mm |
| MDR-20-24 | 24 VDC | 1 A | 24 W | 84% | Active signal | 22.5 mm |
| Model | Output Voltage | Output Current | Rated Power | Efficiency | DC OK | Width |
|---|---|---|---|---|---|---|
| MDR-40-5 | 5 VDC | 6 A | 30 W | 78% | Relay contact | 40 mm |
| MDR-40-12 | 12 VDC | 3.33 A | 40 W | 85% | Relay contact | 40 mm |
| MDR-40-24 | 24 VDC | 1.7 A | 40.8 W | 88% | Relay contact | 40 mm |
| MDR-40-48 | 48 VDC | 0.83 A | 39.8 W | 88% | Relay contact | 40 mm |
| MDR-60-5 | 5 VDC | 10 A | 50 W | 78% | Relay contact | 40 mm |
| MDR-60-12 | 12 VDC | 5 A | 60 W | 85% | Relay contact | 40 mm |
| MDR-60-24 | 24 VDC | 2.5 A | 60 W | 87% | Relay contact | 40 mm |
| MDR-60-48 | 48 VDC | 1.25 A | 60 W | 87% | Relay contact | 40 mm |
| MDR-100-12 | 12 VDC | 7.5 A | 90 W | 83% | Relay contact | 55 mm |
| MDR-100-24 | 24 VDC | 4 A | 96 W | 86% | Relay contact | 55 mm |
| MDR-100-48 | 48 VDC | 2 A | 96 W | 86% | Relay contact | 55 mm |
Ultra-slim plastic housing with a compact footprint designed for space-constrained control cabinets. All dimensions in mm, tolerance ±1 mm.
| Width (W) | 22.5 mm |
| Height (H) | 90 mm |
| Depth (D) | 100 mm |
| Housing | Plastic (blue) |
| Front Panel | DC OK indicator |
| Width (W) | 40 mm |
| Height (H) | 90 mm |
| Depth (D) | 100 mm |
| Housing | Plastic (blue) |
| Front Panel | +V ADJ / DC OK |
| Width (W) | 55 mm |
| Height (H) | 90 mm |
| Depth (D) | 100 mm |
| Housing | Plastic (blue) |
| Front Panel | +V ADJ / DC OK |
The MDR Series supports DIN rail mounting with specific ventilation clearance and orientation requirements for reliable operation.
The appropriate mounting orientation is vertical — input terminals at the bottom and output terminals at the top. Upside-down, horizontal or table-top mounting is not allowed, as sufficient cooling will not be possible.
Always allow good ventilation clearances around the unit: 5 mm left and right, 40 mm above and 20 mm below, to prevent overheating. When the adjacent device is a heat source, keep 10–15 cm clearance.
Admissible DIN rail: TS35/7.5 or TS35/15. Tilt the unit slightly rearwards, fit over the top hat rail, slide it downward until it hits the stop, press against the bottom for locking, then shake slightly to check the locking action.
The FG (Frame Ground) terminal must be connected to PE (Protective Earth) for safety and to ensure proper EMC performance.
Maximum operating temperature: 70°C for MDR-10 / 20 / 40 / 60 (with derating above 50°C); 60°C for MDR-100. Do not install near fire sources or high ambient temperature locations.
Install the unit only in a pollution degree 2 environment — typically dry, well-ventilated locations such as control cabinets. Do not install in places with high moisture or near water.
The MDR Series operates with free air convection cooling and requires adequate ventilation clearance. Do not install in orientations other than vertical, such as upside down, horizontal or table-top mounting.
The MDR Series uses two terminal blocks: TB1 for input and TB2 for output. Use copper wire only and ensure all strands of each stranded wire enter the terminal connection.
| Pin No. | Assignment |
|---|---|
| 1 | FG (Frame Ground) |
| 2 | AC/N |
| 3 | AC/L |
| Pin No. | Assignment |
|---|---|
| 1 | DC OUTPUT +V |
| 2 | DC OUTPUT -V |
| 3 | DC OK active signal |
MDR-10 / 20 use DC OK active signal (no relay contact).
| Pin No. | Assignment |
|---|---|
| 1, 2 | DC OUTPUT +V |
| 3, 4 | DC OUTPUT -V |
| 5, 6 | DC OK relay contact |
MDR-40 / 60 / 100 include a DC OK relay contact (30V/1A resistive load) occupying 2 pins. Contact Close = PSU turns on / DC OK. Contact Open = PSU turns off / DC Fail.
| +V ADJ | DC output voltage adjustment potentiometer (MDR-20 / 40 / 60 / 100 only) |
| DC OK | DC output status indicator LED (all models) |
MDR-10 does not include a +V ADJ potentiometer — the output voltage is fixed.
The FG pin must be connected to PE (Protective Earth). Both -V pins and both +V pins (on MDR-40 / 60 / 100) should be connected to their respective output wires to prevent excessive current stress on a single contact. The two DC OK pins are the relay contact terminals.
| AWG | Rated Current | Cross-section |
|---|---|---|
| 18 | 0–6 A | 0.75 mm² |
| 16 | 6–10 A | 1.00 mm² |
| 14 | 13–16 A | 1.52 mm² |
| 12 | 16–25 A | 2.5 mm² |
Use stranded copper wire only. Use wires that can withstand temperatures of at least 80°C, such as UL1007.
| Model Group | Torque |
|---|---|
| MDR-10 / 20 | 5 kgf-cm (4.4 Lb-in) |
| MDR-40 / 60 / 100 | 5 kgf-cm (4.4 Lb-in) |
Recommended wire strapping length: 5 mm (0.197″). Recommended screwdriver: 3 mm slotted type.
| State | Condition |
|---|---|
| Contact Close | PSU turns on / DC OK |
| Contact Open | PSU turns off / DC Fail |
| Max Rating | 30V / 1A resistive load |
Applies to MDR-40 / 60 / 100. MDR-10 / 20 use DC OK active signal.
The actual wiring should follow the wiring diagram provided in the MDR Series installation manual. Use copper wire only and ensure all strands enter the terminal connection securely.
Read and follow all safety instructions before installing, wiring, maintaining or modifying the MDR Series power supply.
Note: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refers to dry, well-ventilated locations, such as control cabinets.
The MDR Series is suitable for industrial control systems, factory automation equipment, electrical panels, semiconductor manufacturing equipment and hazardous location applications.
Browse all MDR Series DIN rail power supply products, or return to the Industrial Power Supply category page.
The DAPPRA MDR Series is an ultra-slim plastic-housing single-output DIN rail power supply series. It covers 10W, 20W, 40W, 60W and 96W with 5V, 12V, 15V, 24V and 48V output configurations, and is designed for space-constrained industrial control and automation applications.
All MDR Series models support a universal AC input range of 85–264 VAC (single phase) or 120–370 VDC.
The MDR-10 and MDR-20 offer 5V, 12V, 15V and 24V output options. The MDR-40 and MDR-60 offer 5V, 12V, 24V and 48V; the MDR-100 offers 12V, 24V and 48V.
The MDR-40, MDR-60 and MDR-100 models include a DC OK relay contact (30V/1A resistive load) on two terminal pins. The MDR-10 and MDR-20 use a DC OK active signal instead.
Efficiency ranges from 76% (MDR-20-5) up to 88% (MDR-40 and MDR-60 24V/48V models), depending on the model and output voltage.
No-load power consumption is below 0.75W for MDR-10, MDR-20, MDR-40 and MDR-60, and below 1W for MDR-100.
The maximum operating temperature is 70°C for MDR-10, MDR-20, MDR-40 and MDR-60 (with derating above 50°C), and 60°C for MDR-100.
TB1 (Input): Pin 1 = FG, Pin 2 = AC/N, Pin 3 = AC/L. TB2 (Output, MDR-10/20): Pin 1 = +V, Pin 2 = -V, Pin 3 = DC OK active signal. TB2 (Output, MDR-40/60/100): Pin 1,2 = +V, Pin 3,4 = -V, Pin 5,6 = DC OK relay contact.
The MDR Series is certified to UL508, UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 and AS/NZS 60950.1. MDR-40, MDR-60 and MDR-100 are also certified for Class I, Div 2 Hazardous Locations T4.
Select the MDR model according to the required output power (10W to 96W), output voltage, whether a DC OK relay contact is needed, and available DIN rail mounting space in the control cabinet.